ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. B. 理工学域; 数物科学類・物質化学類・機械工学類・フロンティア工学類・電子情報通信学類・地球社会基盤学類・生命理工学類
  2. b 10. 学術雑誌掲載論文
  3. 1.査読済論文(理)

Absolute determination method for trace quantities of enantiomer of glufosinate by γ-cyclodextrin modified capillary zone electrophoresis combined with solid-phase extraction and on-capillary concentration

http://hdl.handle.net/2297/14501
http://hdl.handle.net/2297/14501
dd74c46f-759e-462e-9201-77125afdbf3d
名前 / ファイル ライセンス アクション
SC-PR-IMURA-H-1489.pdf SC-PR-IMURA-H-1489.pdf (92.8 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Absolute determination method for trace quantities of enantiomer of glufosinate by γ-cyclodextrin modified capillary zone electrophoresis combined with solid-phase extraction and on-capillary concentration
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Asami, Takayuki

× Asami, Takayuki

WEKO 17052

Asami, Takayuki

Search repository
Imura, Hisanori

× Imura, Hisanori

WEKO 60
金沢大学研究者情報 60142923
研究者番号 60142923

Imura, Hisanori

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学理工研究域物質化学系
書誌情報 Analytical Sciences

巻 22, 号 12, p. 1489-1493, 発行日 2006-12-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0910-6340
NCID
収録物識別子タイプ NCID
収録物識別子 AA10500785
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.2116/analsci.22.1489
出版者
出版者 日本分析化学会 = Japan Society for Analytical Chemistry
抄録
内容記述タイプ Abstract
内容記述 A highly sensitive and accurate determination method for trace quantities of enantiomers of glufosinate (D,L-GLUF), a phosphorus-containing amino acid-type herbicide, has been studied. The present method is based on the change in the mole ratio of the enantiomeric isomers after spiking of a known amount of an isomer (L-GLUF). The chiral separation and detection were made by γ-cyclodextrin modified capillary zone electrophoresis (γ-CD-CZE) with fluorescence detection. Solid-phase extraction of D,L-GLUF with titania was investigated as the pre-separation method to eliminate coexisting materials such as inorganic salts and organic compounds in river water. A separated D,L-GLUF was labeled with dansyl chloride and subjected to the on-capillary concentration using large-volume sample stacking (LVSS) before γ-CD-CZE. The detection limit of the present method was as low as 2.0 × 10 -9 M. The present method was successfully applied to a model sample containing 2.0 × 10-7 M D,L-GLUF in river water. It was confirmed that trace quantities of D-and L-GLUF in environmental samples can be accurately determined without any calibration curves and comparison standards. 2006 © The Japan Society for Analytical Chemistry.
権利
権利情報 Copyright (c) 2006 by The Japan Society for Analytical Chemistry
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連URI
識別子タイプ URI
関連識別子 http://www.jstage.jst.go.jp/article/analsci/22/12/22_1489/_article
関連URI
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.2116/analsci.22.1489
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 01:33:59.425292
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3