WEKO3
インデックスリンク
アイテム
Absolute determination method for trace quantities of enantiomer of glufosinate by γ-cyclodextrin modified capillary zone electrophoresis combined with solid-phase extraction and on-capillary concentration
http://hdl.handle.net/2297/14501
http://hdl.handle.net/2297/14501dd74c46f-759e-462e-9201-77125afdbf3d
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2017-10-03 | |||||
| タイトル | ||||||
| タイトル | Absolute determination method for trace quantities of enantiomer of glufosinate by γ-cyclodextrin modified capillary zone electrophoresis combined with solid-phase extraction and on-capillary concentration | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| 著者 |
Asami, Takayuki
× Asami, Takayuki× Imura, Hisanori |
|||||
| 提供者所属 | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | 金沢大学理工研究域物質化学系 | |||||
| 書誌情報 |
Analytical Sciences 巻 22, 号 12, p. 1489-1493, 発行日 2006-12-01 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0910-6340 | |||||
| NCID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AA10500785 | |||||
| DOI | ||||||
| 関連タイプ | isIdenticalTo | |||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.2116/analsci.22.1489 | |||||
| 出版者 | ||||||
| 出版者 | 日本分析化学会 = Japan Society for Analytical Chemistry | |||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | A highly sensitive and accurate determination method for trace quantities of enantiomers of glufosinate (D,L-GLUF), a phosphorus-containing amino acid-type herbicide, has been studied. The present method is based on the change in the mole ratio of the enantiomeric isomers after spiking of a known amount of an isomer (L-GLUF). The chiral separation and detection were made by γ-cyclodextrin modified capillary zone electrophoresis (γ-CD-CZE) with fluorescence detection. Solid-phase extraction of D,L-GLUF with titania was investigated as the pre-separation method to eliminate coexisting materials such as inorganic salts and organic compounds in river water. A separated D,L-GLUF was labeled with dansyl chloride and subjected to the on-capillary concentration using large-volume sample stacking (LVSS) before γ-CD-CZE. The detection limit of the present method was as low as 2.0 × 10 -9 M. The present method was successfully applied to a model sample containing 2.0 × 10-7 M D,L-GLUF in river water. It was confirmed that trace quantities of D-and L-GLUF in environmental samples can be accurately determined without any calibration curves and comparison standards. 2006 © The Japan Society for Analytical Chemistry. | |||||
| 権利 | ||||||
| 権利情報 | Copyright (c) 2006 by The Japan Society for Analytical Chemistry | |||||
| 著者版フラグ | ||||||
| 出版タイプ | VoR | |||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
| 関連URI | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | http://www.jstage.jst.go.jp/article/analsci/22/12/22_1489/_article | |||||
| 関連URI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | http://dx.doi.org/10.2116/analsci.22.1489 | |||||