@article{oai:kanazawa-u.repo.nii.ac.jp:00011844, author = {Matsumura, Fumio and 松村, 文夫}, issue = {3}, journal = {金沢大学工学部紀要 = Memoirs of the Faculty of Technology Kanazawa University}, month = {Jun}, note = {Transfer function of silicon controlled rectifier (abbr. SCR) is a very interes­ting problem. For the present. the time delay of the response of SCR circuit has been neglected or expressed by a first order lag. In the previous paper, the transfer function of SCR circuit in an open loop control system was analyzed by means of indicial response method and frequency response method. This paper is intended to make clear the transient response of SCR circuit connecting in a closed loop control system. By the comparison between the indicial response in a real SCR circuit and the simulatiion in an electronic analog computer, the following conclusion is intro­duced: The transfer function of SCR circuit can be approximately expressed by dead time. This result is equal to the conclusion of the previous paper. But, how to evaluate the harmonic response is an important problem and is left in future.}, pages = {95--98}, title = {閉ループ制御系におけるSCR 回路の過渡応答}, volume = {3}, year = {1964} }