@article{oai:kanazawa-u.repo.nii.ac.jp:00011860, author = {Hirai, Eiji and Nakaki, Kazuhiko and Komori, Tomoaki and 平井, 英二 and 中木, 和彦 and 小森, 友明}, issue = {1}, journal = {金沢大学工学部紀要 = Memoirs of the Faculty of Technology Kanazawa University}, month = {Jun}, note = {In studies on a spray column for liquid-liquid extraction, the decision on the number and diameter of the dispersing nozzles appears to be a very important problem for large scale operations. Row, Koffolt and Withrow employed a solvent distributor having 1/16 in., 3/32 in and 1/8 in. holes and indicated that best results were obtained with 1/16 in. holes. However, many of the necessary basic and fundamental data for design and performance of a distributor nozzle are still lacking. This paper deals with the effect of the number and diameter of the dispersing nozzles on the chemical engineering operation of liquid-liquid extraction using a 5.0 cm in diameter and 45 cm long Acrilite resin column, as shown in Fig. 1.}, pages = {56--63}, title = {液液抽出におけるノズルの影響について}, volume = {3}, year = {1962} }