WEKO3
インデックスリンク
アイテム
Semi-automated algorithm for calculating heart-to-mediastinum ratio in cardiac Iodine-123 MIBG imaging
http://hdl.handle.net/2297/26253
http://hdl.handle.net/2297/262536453556a-3b73-43ce-8b43-535f9e376a18
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
Download is available from 9999/12/31.
|
|
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2017-11-09 | |||||
| タイトル | ||||||
| タイトル | Semi-automated algorithm for calculating heart-to-mediastinum ratio in cardiac Iodine-123 MIBG imaging | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| 著者 |
Okuda, Koichi
× Okuda, Koichi× Nakajima, Kenichi× Hosoya, Tetsuo× Ishikawa, Takehiro× Konishi, Takahiro× Matsubara, Kosuke× Matsuo, Shinro× Kinuya, Seigo |
|||||
| 提供者所属 | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | 金沢大学医薬保健研究域医学系 | |||||
| 書誌情報 |
Journal of Nuclear Cardiology 巻 18, 号 1, p. 82-89, 発行日 2011-02-01 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 1071-3581 | |||||
| NCID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AA11016223 | |||||
| DOI | ||||||
| 関連タイプ | isVersionOf | |||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1007/s12350-010-9313-4 | |||||
| 出版者 | ||||||
| 出版者 | Elsevier / American Society of Nuclear Cardiology | |||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Background: We have developed novel software for semi-automatically measuring heart-to-mediastinum (H/M) ratio in cardiac Iodine-123 (123I)-labeled meta-iodobenzylguanidine (MIBG) imaging. Our aim is to improve the reproducibility of the H/M ratio using the semi-automated method as opposed to the manual method. Methods and Results: The software algorithm automatically determined the mediastinal region of interest (ROI) using information from 123I-MIBG uptake of the heart, lung, liver, and thyroid after a cardiac circular ROI was manually set. A total of 37 patients who underwent both early and delayed 123I-MIBG imaging was retrospectively selected. The heart-to-mediastinum (H/M) ratios were calculated by both semi-automated and manual methods and assessed for the intra- and inter-observer variability. All H/M ratios were classified into three groups: normal, slight abnormality, and severe abnormality. The H/M ratios with the new method were higher than those obtained manually (P<.001). In the test-retest reliability, the intra-class correlation coefficient from the semi-automated method showed excellent reproducibility for early (0.99) and delayed (0.99) imaging. The Bland-Altman plots demonstrated better agreement using the semi-automated method (a range of 95% limits -0.11 to 0.10) than that in the manual method (-0.34 to 0.27). The inter-observer agreement was also good using the semi-automated method (κ = 0.866). Conclusions: The H/M ratio using the semi-automated method showed high reproducibility in both early and delayed imaging. © 2010 American Society of Nuclear Cardiology. | |||||
| 著者版フラグ | ||||||
| 出版タイプ | AM | |||||
| 出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
| 関連URI | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | http://www.elsevier.com/locate/issn/10713581 | |||||