{"created":"2023-07-27T06:28:43.527395+00:00","id":13308,"links":{},"metadata":{"_buckets":{"deposit":"2ab11f1a-2c2d-44b7-8909-57bcc310ff2c"},"_deposit":{"created_by":3,"id":"13308","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"13308"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00013308","sets":["4281:4291:4312"]},"author_link":["69263","21479","299","21236","21480","297","116","20090","85235","71925","21296","21579","91300","21578","16634","13121","639"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"16","bibliographicPageStart":"13","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"医用画像情報学会雑誌 = Japan Society of Imaging and Information Sciences in Medicine"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tanaka, Rie"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Sanada, Shigeru"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Fujimura, Masaki"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Yasui, Masahide"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Hayashi, Norio"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Okamoto, Hiroyuki"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Tsuji, Shiro"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Nanbu, Yuko"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsui, Osamu"}],"nameIdentifiers":[{},{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"X-ray translucency of the lungs changes depending on inspired volume. In this study, the usefulness of measuring changes in pixel value on dynamic chest radiographs was assessed in comparison with count of radioactive isotope. In 12 abnormal subjects, there was a good correlation between them (r=0.77) . In eight normal controls, the changes in average pixel value measured in lung unit were almost equal in the right and left lungs, which was consistent with normal respiratory physiology. The results indicated that ventilation performance could be evaluated based on the changes in pixel value on dynamic chest radiographs.","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学医薬保健研究域保健学系","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00013295","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"医用画象情報学会"}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.mii-sci.jp/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jstage.jst.go.jp/article/mii/26/1/26_13/_article/-char/ja/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2009 医用画像情報学会"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10156808","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0910-1543","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田中, 利恵"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"真田, 茂"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"藤村, 政樹"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"安井, 正英"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"林, 則夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"岡本, 博之"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"辻, 志郎"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"南部, 祐子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松井, 修"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"ME-PR-TANAKA-R-13.pdf","filesize":[{"value":"440.7 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"ME-PR-TANAKA-R-13.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/13308/files/ME-PR-TANAKA-R-13.pdf"},"version_id":"30507996-2120-4381-a344-9f9af9eeb0a6"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"胸部X線動画像におけるピクセル値変化量計測の有用性 : 放射性同位元素 (RI) 計数値との比較","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"胸部X線動画像におけるピクセル値変化量計測の有用性 : 放射性同位元素 (RI) 計数値との比較"},{"subitem_title":"Usefulness of measuring changes in pixel value on breathing chest radiographs : Comparison with count of radioactive isotope","subitem_title_language":"en"}]},"item_type_id":"4","owner":"3","path":["4312"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"13308","relation_version_is_last":true,"title":["胸部X線動画像におけるピクセル値変化量計測の有用性 : 放射性同位元素 (RI) 計数値との比較"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T08:48:38.359972+00:00"}