WEKO3
インデックスリンク
アイテム
A comparison of shimming techniques for optimizing fat suppression in MR mammography
http://hdl.handle.net/2297/35701
http://hdl.handle.net/2297/35701664072ec-c925-40e1-80fb-62572fda0bfd
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | A comparison of shimming techniques for optimizing fat suppression in MR mammography | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Takatsu, Yasuo
× Takatsu, Yasuo× Nishiyama, Kengo× Miyachi, Toshiaki× Miyano, Hideto× Kajihara, Mariko× Akasaka, Thai |
|||||
書誌情報 |
Radiological Physics and Technology 巻 6, 号 2, p. 486-491, 発行日 2013-07-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1865-0333 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12236881 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12194-013-0224-3 | |||||
出版者 | ||||||
出版者 | 日本放射線技術学会 / Springer Verlag (Germany) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We evaluated the degree of inhomogeneities of fat suppression using the fully automated three-dimensional breast shimming technique (Image Based-Smart: IB-Smart) and manual setting of a rectangular parallelepiped shim (volume shimming) in MR mammography. Information on breast shape was collected from 9 patients whose images were insufficiently fat-suppressed. A breast phantom made of a thermoplastic sheet was used. Shimming of the magnetic field was done with IB-Smart and various dimensions of volume shims: the anterior to posterior/right to left/head to foot directions were set to 75-150/150-350/50-150 mm. The volumes of inhomogeneously suppressed fat were measured. The calculated volume with inhomogeneous fat suppression with use of IB-Smart was 13.3 × 10 4 mm3. The smallest volume of inhomogeneous fat suppression with volume shimming was 5.4 × 104 mm3 when the anterior-posterior/right-left/head-foot directions were set to 75/350/50 mm. Our results show that using optimized dimensions of volume shims enables better fat suppression than does IB-Smart. © 2013 Japanese Society of Radiological Technology and Japan Society of Medical Physics. | |||||
権利 | ||||||
権利情報 | © 2013 Japanese Society of Radiological Technology and Japan Society of Medical Physics = 日本放射線技術学会 | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |