{"created":"2023-07-27T06:29:01.559898+00:00","id":13672,"links":{},"metadata":{"_buckets":{"deposit":"14c4be04-40b4-489a-88cd-ce0284c593fe"},"_deposit":{"created_by":3,"id":"13672","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"13672"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00013672","sets":["4281:4291:4312"]},"author_link":["299","3018","21909","646","521"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-02-08","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"83135Q","bibliographicVolumeNumber":"8313","bibliographic_titles":[{"bibliographic_title":"Progress in Biomedical Optics and Imaging - Proceedings of SPIE"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田中, 利恵"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"市川, 勝弘"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"松原, 孝祐"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"川嶋, 広貴 "}],"nameIdentifiers":[{},{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Reduction of exposure dose and improvement in image quality can be expected to result from advances in the performance of imaging detectors. We propose a computerized method for determining optimized imaging conditions by use of simulated images. This study was performed to develop a prototype system for image noise and to ensure consistency between the resulting images and actual images. An RQA5 X-ray spectrum was used for determination of input-output characteristics of a flat-panel detector (FPD). The number of incident quantum to the detector per pixel (counts/pixel) was calculated according to the pixel size of the detector and the quantum number in RQA5 determined in IEC6220-1. The relationship among tube current-time product (mAs), exposure dose (C/kg) at the detector surface, the number of incident quanta (counts/pixel), and pixel values measured on the images was addressed, and a conversion function was then created. The images obtained by the FPD was converted into a map of incident quantum numbers and input into random-value generator to simulate image noise. In addition, graphic user interface was developed to observe images with changing image noise and exposure dose levels, which have trade-off relationship. Simulation images provided at different noise levels were compared with actual images obtained by the FPD system. The results indicated that image noise was simulated properly both in objective and subjective evaluation. The present system could allow us to determine necessary dose from image quality and also to estimate image quality from any exposure dose. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).","subitem_description_type":"Abstract"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00013659","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Society of Photo-optical Instrumentation Engineers (SPIE)"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1117/12.909838","subitem_relation_type_select":"DOI"}}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1605-7422","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tanaka, Rie"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Ichikawa, Katsuhiro"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Matsubara, Kosuke"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Kawashima, Hiroki"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"ME-PR-TANAKA-R-8313-210.pdf","filesize":[{"value":"453.9 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"ME-PR-TANAKA-R-8313-210.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/13672/files/ME-PR-TANAKA-R-8313-210.pdf"},"version_id":"41c32e10-710e-4541-ba2d-2472bb6950a6"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Noise simulation system for determining imaging conditions in digital radiography","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Noise simulation system for determining imaging conditions in digital radiography"}]},"item_type_id":"4","owner":"3","path":["4312"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"13672","relation_version_is_last":true,"title":["Noise simulation system for determining imaging conditions in digital radiography"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T08:48:26.162769+00:00"}