{"created":"2023-07-27T06:29:04.215977+00:00","id":13735,"links":{},"metadata":{"_buckets":{"deposit":"0b73bd21-591c-402c-8202-1b6afb667e5f"},"_deposit":{"created_by":3,"id":"13735","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"13735"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00013735","sets":["1132:1133:1134"]},"author_link":["22999","22998","22995","120","22997","22996","23000","20089"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"140","bibliographicPageStart":"136","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"医用画像情報学会雑誌 = Medical Imaging and Information Sciences"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We analysed of the images generated with multi-slice CT in the longitudinal direction (Z) and assessed the noise equivalent quanta (NEQ)evaluation. Evaluation of image quality in NEQ, was possible to accuracy of reappearance in low at high frequency characteristics. In addition, NEQ information was confirmed of usefulness in compared with Winer spectra and MTF method. Examination results suggest that the quantitative analysis in characteristics of image noise and image resolution at multi-slice CT images can provide an optimal parameter for improving quality of images in clinical data.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"医用画像情報学会 = MII: Japan Society of Medical Imaging and Information Sciences"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.11318/mii1984.19.136","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/mii/-char/ja/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.mii-sci.jp/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 医用画像情報学会 MII: Japan Society of Medical Imaging and Information Sciences"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10156808","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0910-1543","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"五味, 勉"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"春日, 敏夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"角谷, 眞澄"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"宮地, 利明"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"越田, 吉郎"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"安藤, 隆"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"上田, 仁"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"佐々木, 祥之"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"ME-PR-MITATI-T-136.pdf","filesize":[{"value":"967.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ME-PR-MITATI-T-136.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/13735/files/ME-PR-MITATI-T-136.pdf"},"version_id":"666fedc3-584c-4ad7-bd7d-e648248f0f99"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"NEQを用いたマルチスライスCTの体軸方向における画質評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"NEQを用いたマルチスライスCTの体軸方向における画質評価"},{"subitem_title":"Evaluation of Characteristic of Longitudinal Direction in Multi-slice CT using NEQ","subitem_title_language":"en"}]},"item_type_id":"4","owner":"3","path":["1134"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"13735","relation_version_is_last":true,"title":["NEQを用いたマルチスライスCTの体軸方向における画質評価"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:59:33.797994+00:00"}