WEKO3
インデックスリンク
アイテム
Maxillary stability after le Fort i osteotomy using three different plate systems
http://hdl.handle.net/2297/31962
http://hdl.handle.net/2297/31962c1d636ee-30b2-4651-bcd2-c6cbd5668ffb
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Maxillary stability after le Fort i osteotomy using three different plate systems | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Ueki, Koichiro
× Ueki, Koichiro× Okabe, Katsuhiko× Moroi, Akinori× Marukawa, Kohei× Sotobori, Megumi× Ishihara, Yuri× Nakagawa, Kiyomasa |
|||||
書誌情報 |
International Journal of Oral and Maxillofacial Surgery 巻 41, 号 8, p. 942-948, 発行日 2012-08-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0901-5027 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10682150 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.ijom.2012.02.023 | |||||
出版者 | ||||||
出版者 | International Association of Oral and Maxillofacial Surgeons | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to compare postoperative changes in maxillary stability after Le Fort I osteotomy in three groups: with an unsintered hydroxyapatite (u-HA)/poly-l-lactic acid (PLLA) plate; a PLLA plate; and a titanium plate. Subjects comprised 60 Japanese patients diagnosed with mandibular prognathism. All patients underwent Le Fort I osteotomy and bilateral sagittal split ramus osteotomy. All patients were randomized in groups of 20 to a u-HA/PLLA group, a PLLA plate group and a titanium plate group. Changes in postoperative time intervals between the plate groups were compared using lateral and posteroanterior cephalography. The uHA/PLLA group had significantly larger values than the PLLA group regarding change of mx1-S perpendicular to SN between 3 and 12 months (T3) (P = 0.0269). The uHA/PLLA group had a significantly larger value than the PLLA group regarding change of S-A perpendicular to SN between baseline and 1 month (T1) (P = 0.0257). There was no significant difference in the other measurements. This study suggests that maxillary stability with satisfactory results could be obtained in the u-HA/PLLA, PLLA plate and titanium plate groups, although there was a slight difference between the u-HA/PLLA and PLLA plate systems in Le Fort I osteotomy. © 2012 International Association of Oral and Maxillofacial Surgeons. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |