{"created":"2023-07-27T06:29:21.184047+00:00","id":14127,"links":{},"metadata":{"_buckets":{"deposit":"2c42962f-cb2f-4e01-ae6e-015446f6b400"},"_deposit":{"created_by":3,"id":"14127","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"14127"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00014127","sets":["1132:1133:1134"]},"author_link":["20089","24124","24125","521"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"166","bibliographicPageStart":"158","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"Radiological Physics and Technology"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Few practical evaluation studies have been conducted on X-ray protective aprons in workplaces. We examined the effects of exchanging the protective apron type with regard to exposure reduction in experimental and practical fields, and discuss the effectiveness of X-ray protective aprons. Experimental field evaluations were performed by the measurement of the X-ray transmission rates of protective aprons. Practical field evaluations were performed by the estimation of the differences in the transit doses before and after the apron exchange. A 0.50-mm lead-equivalent-thick non-lead apron had the lowest transmission rate among the 7 protective aprons, but weighed 10.9 kg and was too heavy. The 0.25 and 0.35-mm lead-equivalent-thick non-lead aprons differed little in the practical field of interventional radiology. The 0.35-mm lead apron had lower X-ray transmission rates and transit doses than the 0.25-mm lead-equivalent- thick non-lead apron, and each of these differences exceeded 8% in the experimental field and approximately 0.15 mSv/month in the practical field of computed tomography (p <0.01). Therefore, we concluded that the 0.25-mm lead-equivalent-thick aprons and 0.35-mm lead apron are effective for interventional radiology operators and computed tomography nurses, respectively. © The Author(s) 2013.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Springer-Verlag"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1007/s12194-013-0246-x","subitem_relation_type_select":"DOI"}}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1865-0341","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Mori, Hiroshige"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Koshida, Kichiro"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Ishigamori, Osamu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsubara, Kosuke"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"ME-PR-MORI-H-158.pdf","filesize":[{"value":"726.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ME-PR-MORI-H-158.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/14127/files/ME-PR-MORI-H-158.pdf"},"version_id":"a2a01c25-45e8-4736-b604-4aa3a36fe6c3"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Evaluation of the effectiveness of X-ray protective aprons in experimental and practical fields","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Evaluation of the effectiveness of X-ray protective aprons in experimental and practical fields"}]},"item_type_id":"4","owner":"3","path":["1134"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"14127","relation_version_is_last":true,"title":["Evaluation of the effectiveness of X-ray protective aprons in experimental and practical fields"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:52:29.493451+00:00"}