Optimization of scan timing for aortic computed tomographic angiography using the test bolus injection technique

http://hdl.handle.net/2297/46179
http://hdl.handle.net/2297/46179
cd68ebb7-2ff8-4586-8e55-24d475da6e0d
名前 / ファイル ライセンス アクション
ME-PR-ICHIKAWA-K-829.pdf ME-PR-ICHIKAWA-K-829.pdf (838.2 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Optimization of scan timing for aortic computed tomographic angiography using the test bolus injection technique
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hoshino, Takashi

× Hoshino, Takashi

WEKO 25308

Hoshino, Takashi

Search repository
Ichikawa, Katsuhiro

× Ichikawa, Katsuhiro

WEKO 646
e-Rad 40402630
金沢大学研究者情報 40402630
研究者番号 40402630

Ichikawa, Katsuhiro

Search repository
Hara, Takanori

× Hara, Takanori

WEKO 25309

Hara, Takanori

Search repository
Terakawa, Shoichi

× Terakawa, Shoichi

WEKO 25310

Terakawa, Shoichi

Search repository
Hosomi, Kazuhiro

× Hosomi, Kazuhiro

WEKO 25311

Hosomi, Kazuhiro

Search repository
Nishimura, Kenji

× Nishimura, Kenji

WEKO 25312

Nishimura, Kenji

Search repository
Takayama, Katsutoshi

× Takayama, Katsutoshi

WEKO 25313

Takayama, Katsutoshi

Search repository
書誌情報 Acta Radiologica

巻 57, 号 7, p. 829-836, 発行日 2016-07-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0284-1851
NCID
収録物識別子タイプ NCID
収録物識別子 AA10668717
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1177/0284185115608659
出版者
出版者 SAGE Publications Inc.
抄録
内容記述タイプ Abstract
内容記述 Background: With fast computed tomography (CT), it is possible for the scanning to outpace the contrast medium bolus during aortic CT angiography (CTA). Purpose: To evaluate the effectiveness of a new method for reducing the risk of outpacing in which the scan start timing (ST) and speed can be estimated from the peak enhancement time measured at the femoral artery using a single testbolus injection (femoral artery test injection method [FTI method]). Material and Methods: In 30 cases of aortic CTA, we measured the time to peak enhancement at the femoral artery (TPF) and the ascending aorta (TPA) with test-bolus injection performed twice in each examination. From the resultant linear relationship between TPF and transit time (TTTPF=TPA), we developed a method for determining the ST and TT from TPF. One hundred patients were assigned to two groups: FTI and bolus tracking (BT), each with 50 patients. CT values were measured in main vessels (ascending aorta, descending aorta, femoral artery). The CT values of the vessels and the rate of cases with more than 300 HU (good cases) were compared between the two groups. Results: The enhancement in the FTI method was significantly higher than that of the BT method (average CT values: FTI, 388.352.4; BT, 281.259.1; P<0.001). The rates of good cases for FTI and BT were 86.0% and 46.0%, respectively. Conclusion: The FTI method was very effective in reducing the risk of outpacing of the contrast medium transit in aortic CTA without the need for an additional contrast medium dose. © The Foundation Acta Radiologica 2015.
内容記述
内容記述タイプ Other
内容記述 Embargo Period 12 months
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 00:47:16.003100
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3