ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Improvement on detectability of early ischemic changes for acute stroke using nonenhanced computed tomography: Effect of matrix size

http://hdl.handle.net/2297/19222
http://hdl.handle.net/2297/19222
14444bd7-c739-4032-a42e-3c4327ecc5b2
名前 / ファイル ライセンス アクション
ME-PR-OGURA-A-162.pdf ME-PR-OGURA-A-162.pdf (776.9 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Improvement on detectability of early ischemic changes for acute stroke using nonenhanced computed tomography: Effect of matrix size
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ogura, Akio

× Ogura, Akio

WEKO 26117

Ogura, Akio

Search repository
Hayakawa, Katsumi

× Hayakawa, Katsumi

WEKO 26118

Hayakawa, Katsumi

Search repository
Miyati, Tosiaki

× Miyati, Tosiaki

WEKO 120
e-Rad 80324086
金沢大学研究者情報 80324086
研究者番号 80324086

Miyati, Tosiaki

Search repository
Maeda, Fumie

× Maeda, Fumie

WEKO 26119

Maeda, Fumie

Search repository
提供者所属
内容記述タイプ Other
内容記述 京都市立病院
提供者所属
内容記述タイプ Other
内容記述 金沢大学医薬保健研究域保健学系
書誌情報 European Journal of Radiology

巻 76, 号 2, p. 162-166, 発行日 2010-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0720-048X
NCID
収録物識別子タイプ NCID
収録物識別子 AA10619405
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1016/j.ejrad.2009.06.013
出版者
出版者 Elsevier
抄録
内容記述タイプ Abstract
内容記述 Purpose: It has recently been reported that intravenous recombinant tissue plasminogen activator improves the clinical outcome after acute stroke. Computed tomography (CT) is the standard imaging method used to determine the indication for thrombolysis. However, detection of early ischemic change often results in an increase in local radiation exposure. Therefore, the effects of decreased matrix size and use of a noise reduction filter were evaluated. Materials and methods: The low contrast resolution was compared for different matrix sizes and imaging filters using a contrast-detail phantom. In addition, early ischemic change in clinical images with matrix sizes of 256 × 256 and 128 × 128 processed using three imaging filters (Gaussian, smoothing, and unsharp mask) from 11 patients within 3 h of stroke onset was evaluated by seven radiologists in a blind manner. Results: The use of images with a matrix size of 256 × 256 and processed with the Gaussian filter increased the detection of early signs of acute stroke. Conclusions: This study was performed to determine whether the converted matrix size and use of imaging filters could improve the detectability of early ischemic change on CT images in acute stroke. To reduce the dose of radiation exposure for patients, it was effective to use an optimal noise reduction filter and reasonable matrix size. In particular, changing the matrix size to 256 × 256 was the most effective for detection of early ischemic change in examinations using clinical images. © 2009 Elsevier Ireland Ltd. All rights reserved.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 00:42:37.788710
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3