WEKO3
インデックスリンク
アイテム
Improvement on detectability of early ischemic changes for acute stroke using nonenhanced computed tomography: Effect of matrix size
http://hdl.handle.net/2297/19222
http://hdl.handle.net/2297/1922214444bd7-c739-4032-a42e-3c4327ecc5b2
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Improvement on detectability of early ischemic changes for acute stroke using nonenhanced computed tomography: Effect of matrix size | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Ogura, Akio
× Ogura, Akio× Hayakawa, Katsumi× Miyati, Tosiaki× Maeda, Fumie |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 京都市立病院 | |||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
European Journal of Radiology 巻 76, 号 2, p. 162-166, 発行日 2010-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0720-048X | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10619405 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.ejrad.2009.06.013 | |||||
出版者 | ||||||
出版者 | Elsevier | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: It has recently been reported that intravenous recombinant tissue plasminogen activator improves the clinical outcome after acute stroke. Computed tomography (CT) is the standard imaging method used to determine the indication for thrombolysis. However, detection of early ischemic change often results in an increase in local radiation exposure. Therefore, the effects of decreased matrix size and use of a noise reduction filter were evaluated. Materials and methods: The low contrast resolution was compared for different matrix sizes and imaging filters using a contrast-detail phantom. In addition, early ischemic change in clinical images with matrix sizes of 256 × 256 and 128 × 128 processed using three imaging filters (Gaussian, smoothing, and unsharp mask) from 11 patients within 3 h of stroke onset was evaluated by seven radiologists in a blind manner. Results: The use of images with a matrix size of 256 × 256 and processed with the Gaussian filter increased the detection of early signs of acute stroke. Conclusions: This study was performed to determine whether the converted matrix size and use of imaging filters could improve the detectability of early ischemic change on CT images in acute stroke. To reduce the dose of radiation exposure for patients, it was effective to use an optimal noise reduction filter and reasonable matrix size. In particular, changing the matrix size to 256 × 256 was the most effective for detection of early ischemic change in examinations using clinical images. © 2009 Elsevier Ireland Ltd. All rights reserved. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |