{"created":"2023-07-27T06:30:10.873330+00:00","id":15090,"links":{},"metadata":{"_buckets":{"deposit":"3894122c-b0ee-4847-ba39-238ff186fc56"},"_deposit":{"created_by":3,"id":"15090","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"15090"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00015090","sets":["1132:1133:1135"]},"author_link":["27156","66","35","207","27157","171","1141"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"8","bibliographicPageEnd":"966","bibliographicPageStart":"962","bibliographicVolumeNumber":"6","bibliographic_titles":[{"bibliographic_title":"Chemical and Pharmaceutical Bulletin"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Twenty-one data sets composed of readings collected by atmospheric ozone monitors worn by individuals on their clothing and installed outside their home or office were collected using Ogawa passive ozone samplers in southeastern Hyogo prefecture, Japan from September 12 to 13, 2011. The concentrations of personal and outdoor ozone ranged from not detectable to 23.2 ppb and from 4.7 to 38.3 ppb, respectively. The mean concentration of personal exposure to ozone was 3.7 ppb and was significantly lower than that of outdoor ozone (18.5 ppb). This suggests that the concentrations of outdoor ozone affect personal ozone exposure. However, in this study, we found no correlation between the concentrations of personal ozone and the total time spent outdoors or the time of day the individual was outside. In contrast, the mean concentrations of outdoor ozone were similar to those of ozone measured at the 12 nearest Ambient Monitoring Stations (AMSs). However, when the AMS was situated near a main road, the regional ozone levels were underestimated.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Pharmaceutical Society of Japan = 日本薬学会"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1248/cpb.c12-00105","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/cpb","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.pharm.or.jp/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2012 The Pharmaceutical Society of Japan 日本薬学会"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA00602100","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0009-2363","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tang, Ning"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Yoda, Yoshiko"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Otani, Naruhito"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kameda, Takayuki"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Toriba, Akira"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Hayakawa, Kazuichi"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Shima, Masayuki"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"PH-PR-NING-T-962.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"PH-PR-NING-T-962.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/15090/files/PH-PR-NING-T-962.pdf"},"version_id":"8441e34b-75b9-475b-9d9b-f3586e43aa0b"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Personal and Atmospheric Concentrations of Ozone in Southeastern Hyogo Prefecture, Japan","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Personal and Atmospheric Concentrations of Ozone in Southeastern Hyogo Prefecture, Japan"}]},"item_type_id":"4","owner":"3","path":["1135"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"15090","relation_version_is_last":true,"title":["Personal and Atmospheric Concentrations of Ozone in Southeastern Hyogo Prefecture, Japan"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:38:31.520099+00:00"}