{"created":"2023-07-27T06:30:14.849328+00:00","id":15187,"links":{},"metadata":{"_buckets":{"deposit":"4664b13e-f067-4d43-a333-daa1be093c7d"},"_deposit":{"created_by":3,"id":"15187","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"15187"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00015187","sets":["1132:1133:1135"]},"author_link":["27423","35","27424","27422","27264"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1995-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"758","bibliographicPageStart":"755","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"Analytical Sciences"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The effect of a mobile phase polyvalent counter ion on the retention behavior and peak intensity of sulfate in non- suppressed ion chromatography was quantitatively studied using a chromatogram simulation method. In this study, both indirect photometric detection (IPD) method and conductometric detection (CD) method were evaluated. With the IPD method, the retention of sulfate was observed to decrease in the presence of the polyvalent counter ion (Trien) without any change in peak intensity. With the CD method, however, peak intensity of sulfate decreased and, under some conditions, gave a negative peak in simulation as was also observed in actual experiments. The present work demonstrates the possibility of predicting the effect of a polyvalent counter ion on sulfate retention without resorting to physical experiments.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本分析化学会 = The Japan Society for Analytical Chemistry"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2116/analsci.11.755","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/analsci","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsac.jp/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © The Japan Society for Analytical Chemistry"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA10500785","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0910-6340","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nishimura, Masayuki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hayashi, Morimasa"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamamoto, Atsushi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hayakawa, Kazuichi"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Miyazaki, Motoichi"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"PH-PR-HAYAKAWA-K-755.pdf","filesize":[{"value":"232.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"PH-PR-HAYAKAWA-K-755.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/15187/files/PH-PR-HAYAKAWA-K-755.pdf"},"version_id":"becc470a-a0c2-43e9-b88d-20daa7869aa2"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Chromatographic Simulation of the Effect of a Polyvalent Counter Ion on Retention Behavior and Peak Intensity of Sulfate","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Chromatographic Simulation of the Effect of a Polyvalent Counter Ion on Retention Behavior and Peak Intensity of Sulfate"}]},"item_type_id":"4","owner":"3","path":["1135"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"15187","relation_version_is_last":true,"title":["Chromatographic Simulation of the Effect of a Polyvalent Counter Ion on Retention Behavior and Peak Intensity of Sulfate"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:36:42.582798+00:00"}