{"created":"2023-07-27T06:30:23.751806+00:00","id":15401,"links":{},"metadata":{"_buckets":{"deposit":"470be6b0-3958-43fd-b9b0-6b27900ed83c"},"_deposit":{"created_by":3,"id":"15401","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"15401"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00015401","sets":["1132:1133:1135"]},"author_link":["20795","28024","66","35","28022","28023","28021"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"123","bibliographicPageStart":"119","bibliographicVolumeNumber":"20","bibliographic_titles":[{"bibliographic_title":"Analytical Sciences"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A method using high-performance liquid chromatography with chemiluminescence detection was developed for analyzing mutagenic nitrobenzanthrone (NBA) isomers in airborne particulates. The method was a modification of our previously described method for analyzing nitropolycyclic aromatic hydrocarbons (NPAHs). The pretreatment and reducing conditions for 1-, 2-, 3- and 10-NBAs were the same as those for NPAHs. In order to separate these NBA isomers, we used a polymeric-type ODS column (Cosmosil 5C-18MS); a mixture of 40% acetonitrile and 60% 10 mM imidazole-HClO4 buffer was employed as the mobile phase at a flow rate of 1 mL/min. The isomers of 1-, 2-, 3- and 10-NBA were determined in chemiluminescence with linear calibration graphs from 0.1 to 4 pmol, from 200 to 4000 pmol, from 1 to 50 pmol and from 10 to 400 pmol, respectively. The detection limits (S/N = 3) of 1-, 2-, 3- and 10-NBA isomers were 0.02 pmol, 35 pmol, 0.3 pmol and 3 pmol, respectively. The method was used to analyze airborne particulates at a heavy traffic site in Kanazawa. 2- and 3-NBAs were detected in the extracts of the particulates, while 1-NBA and 10-NBA were not detected. The atmospheric concentrations of 2- and 3-NBAs were 1.83 pmol/m3 and 24.7 fmol/m3, respectively.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Japan Society for Analytical Chemistry = 日本分析化学会"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2116/analsci.20.119","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsac.or.jp/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://japanlinkcenter.org/JST.JSTAGE/analsci/20.119","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2004 by The Japan Society for Analytical Chemistry"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA10500785","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0910-6340","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tang, Ning"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Taga, Rina"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hattori, Tetsuyuki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tamura, Kenji"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Toriba, Akira"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Kizu, Ryoichi"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Hayakawa, Kazuichi"}],"nameIdentifiers":[{},{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"PH-PR-HAYAKAWA-K-119.pdf","filesize":[{"value":"70.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"PH-PR-HAYAKAWA-K-119.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/15401/files/PH-PR-HAYAKAWA-K-119.pdf"},"version_id":"51b29c2a-4c56-4599-991a-fa18ed4b7f0f"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Determination of Atmospheric Nitrobenzanthrones by High-Performance Liquid Chromatography with Chemiluminescence Detection","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Determination of Atmospheric Nitrobenzanthrones by High-Performance Liquid Chromatography with Chemiluminescence Detection"}]},"item_type_id":"4","owner":"3","path":["1135"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"15401","relation_version_is_last":true,"title":["Determination of Atmospheric Nitrobenzanthrones by High-Performance Liquid Chromatography with Chemiluminescence Detection"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:32:57.123390+00:00"}