{"created":"2023-07-27T06:30:35.157488+00:00","id":15667,"links":{},"metadata":{"_buckets":{"deposit":"662f39b7-574c-42ec-a897-b181aa2e7d6c"},"_deposit":{"created_by":3,"id":"15667","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"15667"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00015667","sets":["1132:1137:1138:1169"]},"author_link":["28884","28883","28887","28885","28886"],"item_7_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1989-05-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"37","bibliographicPageStart":"34","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"核医学画像診断"}]}]},"item_7_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"SPECT画像の劣化を誘発する原因には種々の原因があるが,SPECTの作動中の振動からクリスタル~光電子増倍管系のXY軸回転ズレを起こし,再構成横断画像において解像力の低下を示した","subitem_description_type":"Abstract"}]},"item_7_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"原著論文","subitem_description_type":"Other"}]},"item_7_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"富山医科薬科大学附属病院 放射線","subitem_description_type":"Other"}]},"item_7_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10363063","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0912-4195","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"安井, 正一"}],"nameIdentifiers":[{"nameIdentifier":"28883","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"利波, 修一"}],"nameIdentifiers":[{"nameIdentifier":"28884","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲垣, 晶一"}],"nameIdentifiers":[{"nameIdentifier":"28885","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"瀬戸, 光"}],"nameIdentifiers":[{"nameIdentifier":"28886","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渡辺, 直人"}],"nameIdentifiers":[{"nameIdentifier":"28887","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"C0000003225-124.pdf","filesize":[{"value":"2.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"C0000003225-124.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/15667/files/C0000003225-124.pdf"},"version_id":"bd60922f-a6c8-4730-bdc0-b40c1694eb19"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"核医学","subitem_subject_scheme":"Other"},{"subitem_subject":"放射型コンピュータ断層撮影","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"核医学画像アーチファクト クリスタル~光電子増倍管系のXY軸回転ズレによるSPECT画像の劣化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"核医学画像アーチファクト クリスタル~光電子増倍管系のXY軸回転ズレによるSPECT画像の劣化"}]},"item_type_id":"7","owner":"3","path":["1169"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"15667","relation_version_is_last":true,"title":["核医学画像アーチファクト クリスタル~光電子増倍管系のXY軸回転ズレによるSPECT画像の劣化"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-05-27T06:43:00.710048+00:00"}