{"created":"2023-07-27T06:30:35.199039+00:00","id":15668,"links":{},"metadata":{"_buckets":{"deposit":"2da0cd6c-cf60-4ba7-8fc2-0dd9314fbb99"},"_deposit":{"created_by":3,"id":"15668","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"15668"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00015668","sets":["1132:1137:1138:1169"]},"author_link":["28890","28896","28891","28892","28894","28889","28893","28895","28888"],"item_7_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1989-05-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"40","bibliographicPageStart":"39","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"核医学画像診断"}]}]},"item_7_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ペースメーカ挿入患者のマルチゲート心プールスキャンを行なったところ,ペーシング不全であったため,誤ったデータを算出した症例を報告する。ペースメーカ挿入患者におけるマルチゲート心プールスキャンを行なう際,事前にペーシングが適切に行なわれているか否かを確認すべきであると痛感した。","subitem_description_type":"Abstract"}]},"item_7_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10363063","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0912-4195","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宮崎, 吉春"}],"nameIdentifiers":[{"nameIdentifier":"28888","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"塩崎, 潤"}],"nameIdentifiers":[{"nameIdentifier":"28889","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井上, 寿"}],"nameIdentifiers":[{"nameIdentifier":"28890","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村田, 義治"}],"nameIdentifiers":[{"nameIdentifier":"28891","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤岡, 正彦"}],"nameIdentifiers":[{"nameIdentifier":"28892","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤, 廣"}],"nameIdentifiers":[{"nameIdentifier":"28893","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮永, 盛郎"}],"nameIdentifiers":[{"nameIdentifier":"28894","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷口, 充"}],"nameIdentifiers":[{"nameIdentifier":"28895","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"油野, 民雄"}],"nameIdentifiers":[{"nameIdentifier":"28896","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"C0000003225-125.pdf","filesize":[{"value":"368.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"C0000003225-125.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/15668/files/C0000003225-125.pdf"},"version_id":"5ed9d197-4bf6-4c3b-982d-768b1210e3dc"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"心臓ペースメーカ作用不全症例におけるマルチゲート心プールスキャン","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"心臓ペースメーカ作用不全症例におけるマルチゲート心プールスキャン"}]},"item_type_id":"7","owner":"3","path":["1169"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"15668","relation_version_is_last":true,"title":["心臓ペースメーカ作用不全症例におけるマルチゲート心プールスキャン"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:29:02.766294+00:00"}