{"created":"2023-07-27T06:30:37.210483+00:00","id":15716,"links":{},"metadata":{"_buckets":{"deposit":"86fd57f5-1e10-43d1-aa05-d758a42487ab"},"_deposit":{"created_by":3,"id":"15716","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"15716"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00015716","sets":["1132:1137:1138:1173"]},"author_link":["29093","29096","29094","29095","29097"],"item_7_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1987-12-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"131","bibliographicPageStart":"128","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"核医学画像診断"}]}]},"item_7_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Ⅰ-123およびTc-99m 標識脳血流用剤による頭部SPECT像の深部解像力について,回転型ガンマカメラの回転半径,収集時間を変えて,ファントム実験および臨床例で検討を行った。一般的にはTc-99m標識用剤の方が良好なSPECT像を得ることができたが,大脳基底核部を評価する場合は両薬剤使用時とも,回転半径を小さくすることが不可欠であった。","subitem_description_type":"Abstract"}]},"item_7_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10363063","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0912-4195","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"瀬戸, 光"}],"nameIdentifiers":[{"nameIdentifier":"29093","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"関, 宏恭"}],"nameIdentifiers":[{"nameIdentifier":"29094","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"瀧, 邦康"}],"nameIdentifiers":[{"nameIdentifier":"29095","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柿下, 正雄"}],"nameIdentifiers":[{"nameIdentifier":"29096","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安井, 正一"}],"nameIdentifiers":[{"nameIdentifier":"29097","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"C0000003225-074.pdf","filesize":[{"value":"425.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"C0000003225-074.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/15716/files/C0000003225-074.pdf"},"version_id":"2b033545-fe4a-4528-a6d7-8064a59a56c6"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"回転型ガンマカメラによる頭部SPECT像の問題点: ファントム実験と臨床例の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"回転型ガンマカメラによる頭部SPECT像の問題点: ファントム実験と臨床例の検討"}]},"item_type_id":"7","owner":"3","path":["1173"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"15716","relation_version_is_last":true,"title":["回転型ガンマカメラによる頭部SPECT像の問題点: ファントム実験と臨床例の検討"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:28:17.220173+00:00"}