{"created":"2023-07-27T06:30:38.384958+00:00","id":15744,"links":{},"metadata":{"_buckets":{"deposit":"d493dec4-99c1-4f8a-b70e-2523ad117f15"},"_deposit":{"created_by":3,"id":"15744","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"15744"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00015744","sets":["1132:1137:1138:1175"]},"author_link":["29190","29192","29194","29193","29191"],"item_7_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1987-04-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"37","bibliographicPageStart":"35","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"核医学画像診断"}]}]},"item_7_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"SPECT検査時,腕や金属片等,通常のplanar像にアーチファクトとして影響を及ぼす外的因子がSPECT 像にどのように影響するか,またSPECT回転半径の長短がSPECT像にどのように影響するかを臨床例で検討した。その結果,外的因子は多少なりともSPECT像に影響を及ぼすのでできる限り取り除いた方がよく,また回転半径はできるだけ小さくして検査した方がよい結果が得られた。","subitem_description_type":"Abstract"}]},"item_7_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10363063","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0912-4195","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宮崎, 吉春"}],"nameIdentifiers":[{"nameIdentifier":"29190","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井上, 寿"}],"nameIdentifiers":[{"nameIdentifier":"29191","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"塩崎, 潤"}],"nameIdentifiers":[{"nameIdentifier":"29192","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤岡, 正彦"}],"nameIdentifiers":[{"nameIdentifier":"29193","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"油野, 民雄"}],"nameIdentifiers":[{"nameIdentifier":"29194","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"C0000003225-047.pdf","filesize":[{"value":"357.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"C0000003225-047.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/15744/files/C0000003225-047.pdf"},"version_id":"cc5c867f-b71f-4fa7-824d-427c9ca1ec44"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"外的因子によるSPECT画像上のアーチファクトと近接SPECTの有用性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"外的因子によるSPECT画像上のアーチファクトと近接SPECTの有用性"}]},"item_type_id":"7","owner":"3","path":["1175"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"15744","relation_version_is_last":true,"title":["外的因子によるSPECT画像上のアーチファクトと近接SPECTの有用性"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:27:47.060891+00:00"}