{"created":"2023-07-27T06:31:37.689196+00:00","id":17119,"links":{},"metadata":{"_buckets":{"deposit":"f051e625-9e8f-47bb-986e-b9af5f59700a"},"_deposit":{"created_by":3,"id":"17119","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"17119"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00017119","sets":["1132:1137:1270:1318"]},"author_link":["30818"],"item_7_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-03-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"22","bibliographicPageStart":"13","bibliographicVolumeNumber":"113","bibliographic_titles":[{"bibliographic_title":"金沢大学十全医学会雑誌"}]}]},"item_7_description_16":{"attribute_name":"その他の識別子","attribute_value_mlt":[{"subitem_description":"2004287904","subitem_description_type":"Other"}]},"item_7_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"近年,脊椎腫瘍に対する手術術式として脊椎腫瘍全摘術が広く行われてきているが,これまで脊柱短縮が脊髄に及ぼす影響は解明されていない.そこで,脊柱短縮が脊髄に及ぼす影響について成犬31頭を用いて検討した.脊柱短縮の安全域は脊髄が直線状の形態を維持している12.5mmまでであると考えられた","subitem_description_type":"Abstract"}]},"item_7_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"原著論文","subitem_description_type":"Other"}]},"item_7_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学大学院医学系研究科がん医科学専攻機能再建学","subitem_description_type":"Other"}]},"item_7_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN00044397","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0022-7226","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小林, 忠美"}],"nameIdentifiers":[{"nameIdentifier":"30818","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"C0000002237-016-kobayashi.pdf","filesize":[{"value":"3.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"C0000002237-016-kobayashi.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/17119/files/C0000002237-016-kobayashi.pdf"},"version_id":"955a337a-4635-4acf-8ab3-47950da65ae1"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"運動障害(実験的)","subitem_subject_scheme":"Other"},{"subitem_subject":"血液循環","subitem_subject_scheme":"Other"},{"subitem_subject":"血管造影","subitem_subject_scheme":"Other"},{"subitem_subject":"後肢","subitem_subject_scheme":"Other"},{"subitem_subject":"硬膜","subitem_subject_scheme":"Other"},{"subitem_subject":"整形外科","subitem_subject_scheme":"Other"},{"subitem_subject":"脊髄","subitem_subject_scheme":"Other"},{"subitem_subject":"脊柱","subitem_subject_scheme":"Other"},{"subitem_subject":"麻痺(実験的)","subitem_subject_scheme":"Other"},{"subitem_subject":"体性感覚誘発電位運動麻痺(実験的)","subitem_subject_scheme":"Other"},{"subitem_subject":"脊椎切除術イヌ","subitem_subject_scheme":"Other"},{"subitem_subject":"動物","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"脊柱短縮に伴う脊髄の形態的・生理的変化に関する検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"脊柱短縮に伴う脊髄の形態的・生理的変化に関する検討"}]},"item_type_id":"7","owner":"3","path":["1318"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"17119","relation_version_is_last":true,"title":["脊柱短縮に伴う脊髄の形態的・生理的変化に関する検討"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:07:55.287266+00:00"}