{"created":"2023-07-27T06:31:40.793768+00:00","id":17191,"links":{},"metadata":{"_buckets":{"deposit":"0df8b462-05d8-4b98-a15c-7fb0241015c8"},"_deposit":{"created_by":3,"id":"17191","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"17191"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00017191","sets":["1132:1137:1270:1326"]},"author_link":["30868"],"item_7_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-12-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5・6","bibliographicPageEnd":"389","bibliographicPageStart":"381","bibliographicVolumeNumber":"110","bibliographic_titles":[{"bibliographic_title":"金沢大学十全医学会雑誌"}]}]},"item_7_description_16":{"attribute_name":"その他の識別子","attribute_value_mlt":[{"subitem_description":"2002187009","subitem_description_type":"Other"}]},"item_7_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ヒト網膜電図(ERG)における暗所閾値電位(STR)について検討した.対象は,健康な男性4名(22~32歳)で,明順応後の暗順応経過中の早期の陰性波とSTRの特徴を比較した.60分間の暗順応後では,-5.8logの刺激光強度でSTRが出現し,-4.1logから暗所視系b(bs)波が出現した.5分間の明順応後に暗順応を開始し,一定の刺激光強度下では,暗順応開始後10分程で陰性波が出現し,それはSTRに酷似していた.暗順応開始10分後から刺激光強度を変化させると,-4.4logで陰性波が出現し,-3.4logでbs波が現れた.陰性波の閾値はbs波の閾値より低く,陰性波とbs波の閾値の関係はSTRとbs波の閾値の関係と類似していた.青色と赤色刺激光に対する閾値の対数の差と,明順応後の陰性波の青色と赤色刺激光に対する閾値の対数の差は近似していた.STRは杆体系応答であり,明順応後の陰性波も杆体系応答であった.以上より,陰性波はSTRであり,本STR記録方法によりSTRの臨床応用が可能と考えられた","subitem_description_type":"Abstract"}]},"item_7_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"原著論文","subitem_description_type":"Other"}]},"item_7_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学医系研究脳医科","subitem_description_type":"Other"}]},"item_7_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN00044397","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0022-7226","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田川, 考作"}],"nameIdentifiers":[{"nameIdentifier":"30868","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-04"}],"displaytype":"detail","filename":"C0000002237-008-tagawako.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"C0000002237-008-tagawako.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/17191/files/C0000002237-008-tagawako.pdf"},"version_id":"90d7038b-3713-4943-a2c8-d59e1310d3b0"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"暗順応","subitem_subject_scheme":"Other"},{"subitem_subject":"記録","subitem_subject_scheme":"Other"},{"subitem_subject":"眼球順応","subitem_subject_scheme":"Other"},{"subitem_subject":"ヒト","subitem_subject_scheme":"Other"},{"subitem_subject":"網膜電図閾値","subitem_subject_scheme":"Other"},{"subitem_subject":"電位","subitem_subject_scheme":"Other"},{"subitem_subject":" ヒト","subitem_subject_scheme":"Other"},{"subitem_subject":"成人(19~44)","subitem_subject_scheme":"Other"},{"subitem_subject":"男","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ヒト網膜電図における暗所閾値電位の新しい記録方法の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ヒト網膜電図における暗所閾値電位の新しい記録方法の開発"}]},"item_type_id":"7","owner":"3","path":["1326"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-04"},"publish_date":"2017-10-04","publish_status":"0","recid":"17191","relation_version_is_last":true,"title":["ヒト網膜電図における暗所閾値電位の新しい記録方法の開発"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T00:06:49.708477+00:00"}