ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "0673271f-717d-497c-86a9-f473966557cd"}, "_deposit": {"created_by": 3, "id": "26739", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "26739"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00026739", "sets": ["1763"]}, "author_link": ["45105", "45102", "22059", "45104", "706", "45106", "45103"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-09-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "743", "bibliographicPageStart": "735", "bibliographicVolumeNumber": "31", "bibliographic_titles": [{"bibliographic_title": "医療薬学 = Japanese Journal of Pharmaceutical Health Care and Sciences"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The effectiveness of printing an “Indication Symbol” and the product name on a systemic transdermal absorbent preparation of isosorbide dinitrate (Frandol® tape-S) in preventing medication errors was evaluated through a questionnaire survey of health care professionals and patients. The numbers of completed questionnaire sheets collected for health care professionals were 7, 078 from physicians, 7, 018 from nurses, and 7, 361 from pharmacists (collection rates 70.2-73.6% of the target of 10000). The number of completed questionnaire postcards collected from patients was 1, 339 (44.6% of target of 3, 000). Both health care professionals and patients thought it was a good idea to print an indication symbol, a heart, and the product name on the preparation as a measure to prevent medication errors. Some differences were observed in the answers given to some of the questions among the former, however, indicating the importance of asking many different health care professionals to evaluate measures for preventing medication errors. Sixty percent of the patients returning the questionnaire said that they though it was a good idea to print an indication symbol and product name on the preparation and they had not seen any other product with this feature, but they were not particularly concerned about this. We hope that unified indication symbols will be adopted by all pharmaceutical companies and that their use will be expanded to all categories of systemic transdermal absorbent preparations in order to prevent medication errors.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本医療薬学会 = Japanese Society of Pharmaceutical Health Care and Sciences"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.5649/jjphcs.31.735", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jsphcs.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jjphcs/-char/ja/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110001793463/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © JSPHCS Japanese Society of Pharmaceutical Health Care and Sciences"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11527197", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1346-342X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "古川, 裕之"}], "nameIdentifiers": [{"nameIdentifier": "706", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50361986", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050361986"}]}, {"creatorNames": [{"creatorName": "塚本, 均"}], "nameIdentifiers": [{"nameIdentifier": "45102", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "空閑, 正浩"}], "nameIdentifiers": [{"nameIdentifier": "45103", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "土屋, 文人"}], "nameIdentifiers": [{"nameIdentifier": "45104", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "木村, 昌臣"}], "nameIdentifiers": [{"nameIdentifier": "45105", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大倉, 典子"}], "nameIdentifiers": [{"nameIdentifier": "45106", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮本, 謙一"}], "nameIdentifiers": [{"nameIdentifier": "22059", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30100514", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030100514"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "HO-PR-MIYAMOTO-K-735.pdf", "filesize": [{"value": "1.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1600000.0, "url": {"label": "HO-PR-MIYAMOTO-K-735.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/26739/files/HO-PR-MIYAMOTO-K-735.pdf"}, "version_id": "1eed09a4-69fa-42d5-8547-18d360ff4728"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "medication error", "subitem_subject_scheme": "Other"}, {"subitem_subject": "patient safety", "subitem_subject_scheme": "Other"}, {"subitem_subject": "human error", "subitem_subject_scheme": "Other"}, {"subitem_subject": "indication symbol", "subitem_subject_scheme": "Other"}, {"subitem_subject": "systemic transdermal absorbent preparation", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "硝酸イソソルビド経皮吸収型製剤で試みた使用の安全対策「薬効マーク」に対する医療従事者と患者の評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "硝酸イソソルビド経皮吸収型製剤で試みた使用の安全対策「薬効マーク」に対する医療従事者と患者の評価"}, {"subitem_title": "Evaluation of Health Care Professionals and Patients Opinions of “Indication Symbol” Printed on Systemic Transdermal Absorbent Preparation of Isosorbide Dinitrate to Prevent Medication Errors", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1763"], "permalink_uri": "http://hdl.handle.net/2297/36330", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-05"}, "publish_date": "2017-10-05", "publish_status": "0", "recid": "26739", "relation": {}, "relation_version_is_last": true, "title": ["硝酸イソソルビド経皮吸収型製剤で試みた使用の安全対策「薬効マーク」に対する医療従事者と患者の評価"], "weko_shared_id": -1}
  1. G. 附属病院
  2. g 10. 学術雑誌掲載論文
  3. 1. 査読済論文

硝酸イソソルビド経皮吸収型製剤で試みた使用の安全対策「薬効マーク」に対する医療従事者と患者の評価

http://hdl.handle.net/2297/36330
http://hdl.handle.net/2297/36330
df1d403d-d048-4553-ace4-50f8eca19faf
名前 / ファイル ライセンス アクション
HO-PR-MIYAMOTO-K-735.pdf HO-PR-MIYAMOTO-K-735.pdf (1.6 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-05
タイトル
タイトル 硝酸イソソルビド経皮吸収型製剤で試みた使用の安全対策「薬効マーク」に対する医療従事者と患者の評価
タイトル
言語 en
タイトル Evaluation of Health Care Professionals and Patients Opinions of “Indication Symbol” Printed on Systemic Transdermal Absorbent Preparation of Isosorbide Dinitrate to Prevent Medication Errors
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 古川, 裕之

× 古川, 裕之

WEKO 706
研究者番号 50361986

古川, 裕之

Search repository
塚本, 均

× 塚本, 均

WEKO 45102

塚本, 均

Search repository
空閑, 正浩

× 空閑, 正浩

WEKO 45103

空閑, 正浩

Search repository
土屋, 文人

× 土屋, 文人

WEKO 45104

土屋, 文人

Search repository
木村, 昌臣

× 木村, 昌臣

WEKO 45105

木村, 昌臣

Search repository
大倉, 典子

× 大倉, 典子

WEKO 45106

大倉, 典子

Search repository
宮本, 謙一

× 宮本, 謙一

WEKO 22059
研究者番号 30100514

宮本, 謙一

Search repository
書誌情報 医療薬学 = Japanese Journal of Pharmaceutical Health Care and Sciences

巻 31, 号 9, p. 735-743, 発行日 2005-09-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 1346-342X
NCID
収録物識別子タイプ NCID
収録物識別子 AA11527197
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.5649/jjphcs.31.735
出版者
出版者 日本医療薬学会 = Japanese Society of Pharmaceutical Health Care and Sciences