WEKO3
インデックスリンク
アイテム
Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography
http://hdl.handle.net/2297/45932
http://hdl.handle.net/2297/459326befe847-8e76-4743-afd0-51220ddbfcfc
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]()
Download is available from 9999/12/31.
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-09 | |||||
タイトル | ||||||
タイトル | Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Yoneyama, Hiroto
× Yoneyama, Hiroto× Nakajima, Kenichi× Okuda, Koichi× Matsuo, Shinro× Onoguchi, Masahisa× Kinuya, Seigo× Edenbrandt, Lars |
|||||
書誌情報 |
Journal of Nuclear Cardiology 巻 24, 号 4, p. 1378-1388, 発行日 2017-08-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1071-3581 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11016223 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12350-016-0518-z | |||||
出版者 | ||||||
出版者 | Springer New York LLC | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background: We compared two reconstruction algorisms and two cardiac functional evaluation software programs in terms of their accuracy for estimating ejection fraction (EF) of small hearts (SH). Methods: The study group consisted of 66 pediatric patients. Data were reconstructed using a filtered back projection (FBP) method without the resolution correction (RC) and an iterative method based on an ordered subset expectation maximization (OSEM) algorithm with the RC. EF was evaluated using two software programs of quantitative gated single-photon emission computed tomography (SPECT) (QGS) and cardioREPO. We compared the EF of gated myocardial perfusion SPECT to echocardiographic measurement (Echo). Results: Forty-eight of 66 patients had an end-systolic volume < 20 mL which was used as the criterion for being included in the SH group, and the SH effect led to an overestimation of EF. While significant differences were observed between Echo (66.9 ± 5.0%) and QGS-FBP without RC (76.9 ± 8.4%, P < .0001), QGS-OSEM with RC (76.6 ± 8.6%, P < .0001), and cardioREPO-FBP without RC (72.1 ± 10.0%, P = .0011), no significant difference was observed between Echo and cardioREPO-OSEM with RC (67.4 ± 6.1%) in SH group. Conclusions: In pediatric gated myocardial perfusion SPECT, the SH effect can be significantly reduced when an OSEM algorithm is used with RC in combination with the specific cardioREPO algorithm. © 2016 American Society of Nuclear Cardiology | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Embargo Period 12 months | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |