{"created":"2023-07-27T06:40:27.552045+00:00","id":29287,"links":{},"metadata":{"_buckets":{"deposit":"af0ee67c-dff3-4d2d-a16d-966778c19c3e"},"_deposit":{"created_by":3,"id":"29287","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"29287"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00029287","sets":["1979:1980:1981"]},"author_link":["11069","50260","50261","11068"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-10-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageEnd":"3639","bibliographicPageStart":"3637","bibliographicVolumeNumber":"41","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Magnetics"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The precise measurement of two-dimensional and three-dimensional magnetic flux distribution is indispensable for the development of magnetic machinery and device. The magnetic computed tomography (CT) method is proposed to visualize magnetic flux distribution. In order to determine the optimum structure of the magnetic CT probe, an evaluation model is employed to simulate the reconstruction accuracy of magnetic flux distribution. The spectrum of a distribution of magnetic field has been discussed of the components. As a result, the numerical simulation shows the optimum design of the multi layer CT probe. © 2005 IEEE.","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学環日本海域環境研究センター生体機能計測研究部門","subitem_description_type":"Other"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/TMAG.2005.855175","subitem_relation_type_select":"DOI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© IEEE 2005"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA00667933","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0018-9464","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nishimura, T."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Miyamoto, Y."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamada, Sotoshi"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Iwahara, Masayoshi"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-05"}],"displaytype":"detail","filename":"TE-PR-YAMADA-S-11.pdf","filesize":[{"value":"445.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-YAMADA-S-11.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/29287/files/TE-PR-YAMADA-S-11.pdf"},"version_id":"39c80d58-8522-4b00-b49f-b730682c2476"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Optimum structure of CT probe and spectral components in 2-D magnetic field visualization based on the magnetic CT method","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Optimum structure of CT probe and spectral components in 2-D magnetic field visualization based on the magnetic CT method"}]},"item_type_id":"4","owner":"3","path":["1981"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-05"},"publish_date":"2017-10-05","publish_status":"0","recid":"29287","relation_version_is_last":true,"title":["Optimum structure of CT probe and spectral components in 2-D magnetic field visualization based on the magnetic CT method"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-27T20:37:45.741145+00:00"}