{"created":"2023-07-27T06:48:29.180131+00:00","id":40007,"links":{},"metadata":{"_buckets":{"deposit":"7c529a72-c39f-450a-9f62-954b5e8c2ca8"},"_deposit":{"created_by":3,"id":"40007","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"40007"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00040007","sets":["4161:3020:3021"]},"author_link":["366","11946","1779","63438"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageStart":"73707","bibliographicVolumeNumber":"82","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"福間, 剛士"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"淺川, 雅"}],"nameIdentifiers":[{},{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have developed a wideband phase-locked loop (PLL) circuit with real-time phase correction for high-speed and accurate force measurements by frequency modulation atomic force microscopy (FM-AFM) in liquid. A high-speed operation of FM-AFM requires the use of a high frequency cantilever which, however, increases frequency-dependent phase delay caused by the signal delay within the cantilever excitation loop. Such phase delay leads to an error in the force measurements by FM-AFM especially with a low Q factor. Here, we present a method to compensate this phase delay in real time. Combined with a wideband PLL using a subtraction-based phase comparator, the method allows to perform an accurate and high-speed force measurement by FM-AFM. We demonstrate the improved performance by applying the developed PLL to three-dimensional force measurements at a mica/water interface. © 2011 American Institute of Physics.","subitem_description_type":"Abstract"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00039994","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"American Institute of Physics (AIP)"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.3608447","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://rsi.aip.org/resource/1/rsinak/v82/i7/p073707_s1?isAuthorized=no","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2011 American Institute of Physics"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA00817730","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0034-6748","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Fukuma, Takeshi"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Yoshioka, Shunsuke"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Asakawa, Hitoshi"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-06"}],"displaytype":"detail","filename":"FR-PR-FUKUMA-T-73707.pdf","filesize":[{"value":"746.6 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"FR-PR-FUKUMA-T-73707.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/40007/files/FR-PR-FUKUMA-T-73707.pdf"},"version_id":"ecfc0c1d-0a52-4928-bf82-752e3c847f50"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Wideband phase-locked loop circuit with real-time phase correction for frequency modulation atomic force microscopy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Wideband phase-locked loop circuit with real-time phase correction for frequency modulation atomic force microscopy"}]},"item_type_id":"4","owner":"3","path":["3021"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-06"},"publish_date":"2017-10-06","publish_status":"0","recid":"40007","relation_version_is_last":true,"title":["Wideband phase-locked loop circuit with real-time phase correction for frequency modulation atomic force microscopy"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T10:35:14.908051+00:00"}