{"created":"2023-07-27T06:50:03.707870+00:00","id":42503,"links":{},"metadata":{"_buckets":{"deposit":"bd1c53dd-69a4-4656-8573-c7d3c1d6c893"},"_deposit":{"created_by":18,"id":"42503","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"42503"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00042503","sets":["934:935:937"]},"author_link":["2690","67545","67546","67541","145","67544","67548","67547","67543"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-08-15","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"199","bibliographicPageStart":"190","bibliographicVolumeNumber":"1060","bibliographic_titles":[{"bibliographic_title":"Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λmax = 405.8 nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5 ng mL−1, respectively. The precision, as relative standard deviation, was lower than 5% at 0.1 μg mL−1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate: >95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5 min, without preconcentration) with a reliable detection limit at trace levels. © 2017 Elsevier B.V.","subitem_description_type":"Abstract"}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"著者所属: 金沢大学理工研究域物質化学系","subitem_description_type":"Other"},{"subitem_description":"Embargo Period 12 months","subitem_description_type":"Other"}]},"item_10001_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00048858","subitem_identifier_reg_type":"JaLC"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier B.V."}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.jchromb.2017.06.016","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.elsevier.com/locate/issn/15700232"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.elsevier.com/locate/issn/15700232","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © Elsevier B.V. (CC-BY NC ND) "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA1116375X","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1570-0232","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"牧, 輝弥"},{"creatorName":"マキ, テルヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2690","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"70345601","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=70345601"},{"nameIdentifier":"70345601","nameIdentifierScheme":"金沢大学研究者情報","nameIdentifierURI":"http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=70345601"},{"nameIdentifier":"70345601","nameIdentifierScheme":"研究者番号","nameIdentifierURI":"https://nrid.nii.ac.jp/nrid/1000070345601"}]},{"creatorNames":[{"creatorName":"長谷川, 浩"},{"creatorName":"ハセガワ, ヒロシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"145","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"90253335","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=90253335"},{"nameIdentifier":"90253335","nameIdentifierScheme":"金沢大学研究者情報","nameIdentifierURI":"http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=90253335"},{"nameIdentifier":"90253335","nameIdentifierScheme":"研究者番号","nameIdentifierURI":"https://nrid.nii.ac.jp/nrid/1000090253335"}]},{"creatorNames":[{"creatorName":"Suman, Barua","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67541","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ismail M. M., Rahman","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67543","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iftakharul, Alam ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67544","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Maho, Miyaguchi ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67545","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hikaru, Sawai ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67546","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Teruya, Maki ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67547","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiroshi, Hasegawa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67548","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-08-16"}],"displaytype":"detail","filename":"TE-PR-HASEGAWA-H-190.pdf","filesize":[{"value":"518.6 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"TE-PR-HASEGAWA-H-190.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/42503/files/TE-PR-HASEGAWA-H-190.pdf"},"version_id":"61449f45-9153-4246-80b6-872a026beb16"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Lead","subitem_subject_scheme":"Other"},{"subitem_subject":"LEP-OES","subitem_subject_scheme":"Other"},{"subitem_subject":"On-site analysis","subitem_subject_scheme":"Other"},{"subitem_subject":"Preconcentration","subitem_subject_scheme":"Other"},{"subitem_subject":"Selective separation","subitem_subject_scheme":"Other"},{"subitem_subject":"Solid-phase extraction","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead"}]},"item_type_id":"10001","owner":"18","path":["937"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-11-17"},"publish_date":"2017-11-17","publish_status":"0","recid":"42503","relation_version_is_last":true,"title":["Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead"],"weko_creator_id":"18","weko_shared_id":18},"updated":"2023-07-27T15:16:14.168382+00:00"}