{"created":"2023-07-27T06:50:04.428013+00:00","id":42534,"links":{},"metadata":{"_buckets":{"deposit":"e7d3ce9e-d246-4a7e-822c-07a60a994a8d"},"_deposit":{"created_by":18,"id":"42534","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"42534"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00042534","sets":["934:935:936"]},"author_link":["67721","67723","67725","67724","67722","67720","67719"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1581205","bibliographicPageEnd":"162","bibliographicPageStart":"157","bibliographicVolumeNumber":"2006","bibliographic_titles":[{"bibliographic_title":"Proceedings - Third IEEE International Workshop on Electronic Design, Test and Applications, DELTA 2006 \\n2006,1581205"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We present an eddy-current test (ECT) method for detecting conductive microbeads on a non-conductive substrate. A Helmholtz coil is used to generate an exciting magnetic field. The magnetic fields, generated by eddy-currents in a Pb-Sn microbead, are detected by a spin-valve giant magnetoresistive (SV-GMR) sensor. The experimental results are compared to an analytical solution for the magnetic field over the microbead. Early results for the detection of a grid of microbeads are also presented. © 2005 IEEE.","subitem_description_type":"Abstract"}]},"item_10001_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00048889","subitem_identifier_reg_type":"JaLC"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/DELTA.2006.25 ","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © IEEE"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山田, 外史"}],"nameIdentifiers":[{"nameIdentifier":"67719","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"80019786","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=80019786"}]},{"creatorNames":[{"creatorName":"岩原, 正吉"}],"nameIdentifiers":[{"nameIdentifier":"67720","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"80020212","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=80020212"}]},{"creatorNames":[{"creatorName":"T., Somsak","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67721","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"K., Chomsuwan","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67722","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sotoshi, Yamada","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67723","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masayoshi, Iwahara","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67724","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"S.C., Mukhopadhyay","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67725","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-11-16"}],"displaytype":"detail","filename":"TE-PR-YAMADA-S-258.pdf","filesize":[{"value":"612.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-YAMADA-S-258.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/42534/files/TE-PR-YAMADA-S-258.pdf"},"version_id":"42117bee-b8ba-4691-8037-2eeba3110810"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Conductive microbead","subitem_subject_scheme":"Other"},{"subitem_subject":"Eddy-current testing","subitem_subject_scheme":"Other"},{"subitem_subject":"Helmholtz coil","subitem_subject_scheme":"Other"},{"subitem_subject":"Spin-valve giant magnetoresistance\\n","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Conductive Microbead Detection by Helmholtz Coil Technique With SV-GMR Sensor","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Conductive Microbead Detection by Helmholtz Coil Technique With SV-GMR Sensor"}]},"item_type_id":"10001","owner":"18","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-11-16"},"publish_date":"2017-11-16","publish_status":"0","recid":"42534","relation_version_is_last":true,"title":["Conductive Microbead Detection by Helmholtz Coil Technique With SV-GMR Sensor"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T17:50:35.296072+00:00"}