{"created":"2023-07-27T06:50:05.147353+00:00","id":42559,"links":{},"metadata":{"_buckets":{"deposit":"d0880c2c-b460-4079-8998-49bec1895776"},"_deposit":{"created_by":18,"id":"42559","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"42559"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00042559","sets":["934:935:936"]},"author_link":["67852","67853","67854","67856","67857","67855"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"109","bibliographicPageStart":"106","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"Journal of the Japan Society of Applied Electromagnetics and Mechanics = 日本AEM学会誌"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The main aim of this article is to present the possibility to estimate the content density of magnetic fluid in various shape cavities by SV-GMR needle type probe. Changes caused by the shape and amount of ferrite included in cavity were examined. Analytical model and numerical calculation were performed to confirm these results. We assume that if the signal changes are linearly dependent on magnetic permeability of sample and with known shape ratio it is possible to estimate the amount of the iron consisted in the sample.","subitem_description_type":"Abstract"}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Special Issue of the Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM10)","subitem_description_type":"Other"}]},"item_10001_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00048913","subitem_identifier_reg_type":"JaLC"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本AEM学会 = The Japan Society of Applied Electromagnetics "}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://www.jstage.jst.go.jp/browse/jsaem/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/jsaem/","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.jsaem.gr.jp/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsaem.gr.jp/","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 日本AEM学会 The Japan Society of Applied Electromagnetics and Mechanics"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10457520","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0919-4452 ","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山田, 外史"}],"nameIdentifiers":[{"nameIdentifier":"67852","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柿川, 真紀子"}],"nameIdentifiers":[{"nameIdentifier":"67853","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"R.G., Haraszczuk","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67854","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sotoshi, Yamada","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67855","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Makiko, Kakikawa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67856","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"C.P., Gooneratne","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67857","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-11-16"}],"displaytype":"detail","filename":"TE-PR-YAMADA-S-310.pdf","filesize":[{"value":"939.4 kB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"TE-PR-YAMADA-S-310.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/42559/files/TE-PR-YAMADA-S-310.pdf"},"version_id":"6f0b7fdb-b942-488d-af9f-2fec45385fe8"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"GMR sensor","subitem_subject_scheme":"Other"},{"subitem_subject":"Demagnetizing factor","subitem_subject_scheme":"Other"},{"subitem_subject":"Magnetic nanoparticles","subitem_subject_scheme":"Other"},{"subitem_subject":"Lee Whiting coil","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe"}]},"item_type_id":"10001","owner":"18","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-11-16"},"publish_date":"2017-11-16","publish_status":"0","recid":"42559","relation_version_is_last":true,"title":["Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T17:49:47.939844+00:00"}