{"created":"2023-07-27T06:50:05.283061+00:00","id":42562,"links":{},"metadata":{"_buckets":{"deposit":"e2295221-a9c4-4282-8143-7c0b9c615291"},"_deposit":{"created_by":18,"id":"42562","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"42562"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00042562","sets":["934:935:936"]},"author_link":["67876","67875","67878","67872","67871","67874","67873","67877"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"66","bibliographicPageStart":"63","bibliographicVolumeNumber":"17","bibliographic_titles":[{"bibliographic_title":"Journal of the Japan Society of Applied Electromagnetics and Mechanics = 日本AEM学会誌"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Utilization of magnetic nanoparticles in biomedicine has seen an unprecedented growth in recent years. The ability to accurately estimate magnetic nanoparticles inside small areas of the body provides an advantage in hyperthermia therapy, a form of cancer treatment. This paper concentrates on a novel giant magnetoresistance (GMR) needle-type sensor to detect and estimate low concentration magnetic fluid inside minute agar cavities injected with magnetic fluid. Theoretical analysis, experimental results and information on the fabricated GMR needle-type sensor are reported. The experimental results show a favorable agreement to the analytical analysis, supporting the potential use of the GMR needle-type sensor in hyperthermia therapy.","subitem_description_type":"Abstract"}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08)","subitem_description_type":"Other"}]},"item_10001_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00048916","subitem_identifier_reg_type":"JaLC"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本AEM学会 = The Japan Society of Applied Electromagnetics "}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://www.jstage.jst.go.jp/browse/jsaem/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/jsaem/","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.jsaem.gr.jp/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsaem.gr.jp/","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 日本AEM学会 The Japan Society of Applied Electromagnetics and Mechanics"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10457520","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0919-4452 ","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山田, 外史"}],"nameIdentifiers":[{"nameIdentifier":"67871","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩原, 正吉"}],"nameIdentifiers":[{"nameIdentifier":"67872","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柿川, 真紀子"}],"nameIdentifiers":[{"nameIdentifier":"67873","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"C.P., Gooneratne","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67874","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sotoshi, Yamada","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67875","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masayoshi, Iwahara","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67876","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Makiko, Kakikawa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67877","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Y., Matsumoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"67878","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-11-16"}],"displaytype":"detail","filename":"TE-PR-YAMADA-S-290.pdf","filesize":[{"value":"321.4 kB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"TE-PR-YAMADA-S-290.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/42562/files/TE-PR-YAMADA-S-290.pdf"},"version_id":"425dc0d8-7826-4687-be7c-6f197f4aafb0"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"giant magnetoresistance","subitem_subject_scheme":"Other"},{"subitem_subject":"hyperthermia therapy","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic nanoparticles","subitem_subject_scheme":"Other"},{"subitem_subject":"demagnetizing factor","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities"}]},"item_type_id":"10001","owner":"18","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-11-16"},"publish_date":"2017-11-16","publish_status":"0","recid":"42562","relation_version_is_last":true,"title":["Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T17:49:52.277110+00:00"}