{"created":"2023-07-27T06:50:11.684712+00:00","id":42868,"links":{},"metadata":{"_buckets":{"deposit":"16f3aad6-87b0-4a80-a70c-21738769a93a"},"_deposit":{"created_by":18,"id":"42868","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"42868"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00042868","sets":["934:935:936"]},"author_link":["68563","68562","67651","68564","73446","73447"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-02-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"685","bibliographicPageStart":"681","bibliographicVolumeNumber":"23","bibliographic_titles":[{"bibliographic_title":"日本AEM学会誌"},{"bibliographic_title":"Journal of the Japan Society of Applied Electromagnetics","bibliographic_titleLang":"en"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yamada, Sotoshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ikehata, Yoshio"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hayashi, Ryohei"}],"nameIdentifiers":[{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Induction heating type hyperthermia treatment needs both high magnetic fields (> 2 mT) and a few hundred kHz inside of a body to heat magnetic particles and implant materials up to 43°C. We proposed the double-pancake type coils sandwiching human body。 The exciting coils of human scale could generate magnetic fields with both magnitude and frequency required to a medical treatment. In order to make magnetic fields inside a deep body further increase, we proposed that a back yoke as magnetic materials was added to both coils. The paper discussed magnetic- and electrical-circuit characteristics of the coils with a magnetic sheet and ferrite as back yoke. ","subitem_description_type":"Abstract"}]},"item_4_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Special Issue on The 23rd MAGDA Conference in Takamatsu (MAGDA2014)","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00049217","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本AEM学会"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.14243/jsaem.23.681","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.jsaem.gr.jp/index.html"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsaem.gr.jp/index.html","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://www.jstage.jst.go.jp/browse/jsaem"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/jsaem","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 日本AEM学会 The Japan Society of Applied Electromagnetics and Mechanics"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10457520","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0919-4452","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山田, 外史"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"池畑, 芳雄"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"林, 亮平"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-12-07"}],"displaytype":"detail","filename":"TE-PR-YAMADA-S-681.pdf","filesize":[{"value":"1.7 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"TE-PR-YAMADA-S-681.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/42868/files/TE-PR-YAMADA-S-681.pdf"},"version_id":"08a79a85-5efd-4ea3-9fd1-f56b8afb0a43"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"磁気シートで構成したバックヨーク付医療用磁界発生装置の研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"磁気シートで構成したバックヨーク付医療用磁界発生装置の研究"},{"subitem_title":"Applicator Added Back Yoke Composed of Magnetic Sheet for Hyperthermia Therapy","subitem_title_language":"en"}]},"item_type_id":"4","owner":"18","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-12-07"},"publish_date":"2017-12-07","publish_status":"0","recid":"42868","relation_version_is_last":true,"title":["磁気シートで構成したバックヨーク付医療用磁界発生装置の研究"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T17:39:49.057158+00:00"}