{"created":"2023-07-27T06:50:51.716312+00:00","id":44006,"links":{},"metadata":{"_buckets":{"deposit":"255ca8cc-795e-4141-a4a5-e0eff331d2f5"},"_deposit":{"created_by":18,"id":"44006","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"44006"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00044006","sets":["934:935:936"]},"author_link":["72900","73215","73217","71731","73213","73219","73216","73220"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"C67","bibliographicPageEnd":"142","bibliographicPageStart":"141","bibliographicVolumeNumber":"2013 Autumn","bibliographic_titles":[{"bibliographic_title":"精密工学会学術講演会講演論文集"},{"bibliographic_title":"2013 JSPE Autumn Conference","bibliographic_titleLang":"en"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Murai, Yuuki"}],"nameIdentifiers":[{"nameIdentifier":"73217","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Seki, Hiroaki"}],"nameIdentifiers":[{"nameIdentifier":"71731","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"20270887","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=20270887"}]},{"creatorNames":[{"creatorName":"Yamaguchi, Yasuaki"}],"nameIdentifiers":[{"nameIdentifier":"73219","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ri, Bai"}],"nameIdentifiers":[{"nameIdentifier":"73220","nameIdentifierScheme":"WEKO"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"重量物をクレーンにより吊り上げる際,荷物の重心とクレーンフックの位置がずれていると荷物が横ずれし,作業者を巻き込む事故が発生しやすい.荷物の偏心量を測定し正しい位置にクレーンフックをかけられれば安全である.本研究では荷物の前後左右に力センサを配置し,吊り上げる際に発生する力を測定して,吊り上げ力も含めた力の関係から偏心量を検出する方法を提案する.約10Kgの荷物モデルの吊り上げ実験により可能性を示せた.","subitem_description_type":"Abstract"}]},"item_4_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"出版者照会後に全文公開","subitem_description_type":"Other"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学理工研究域機械工学系","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00050348","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"精密工学会 = The Japan Society for Precision Engineering"}]},"item_4_relation_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"BA90159927","subitem_relation_type_select":"NCID"}}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.11522/pscjspe.2013A.0.141.0","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://www.jstage.jst.go.jp/browse/pscjspe/-char/ja/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/pscjspe/-char/ja/","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.jspe.or.jp/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jspe.or.jp/","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.jspe.or.jp/publication/ext_site/jstage/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jspe.or.jp/publication/ext_site/jstage/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © The Japan Society for Precision Engineering"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"村井, 祐貴"}],"nameIdentifiers":[{"nameIdentifier":"73213","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"関, 啓明"}],"nameIdentifiers":[{"nameIdentifier":"72900","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"20270887","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=20270887"}]},{"creatorNames":[{"creatorName":"山口, 安昭"}],"nameIdentifiers":[{"nameIdentifier":"73215","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"李, 倍"}],"nameIdentifiers":[{"nameIdentifier":"73216","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-06-15"}],"displaytype":"detail","filename":"TE-PR-SEKI-H-141.pdf","filesize":[{"value":"668.2 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"TE-PR-SEKI-H-141.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/44006/files/TE-PR-SEKI-H-141.pdf"},"version_id":"fb1b8dda-0478-4914-9b05-71ee259113c9"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"クレーン荷物吊り上げ時の偏心検出システム(第1報): 基本構成とモデル実験","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"クレーン荷物吊り上げ時の偏心検出システム(第1報): 基本構成とモデル実験"},{"subitem_title":"Sensing System to Detect Center of Gravity of a Lifting Load for a Crane: Basic Concept and Model Experiment","subitem_title_language":"en"}]},"item_type_id":"4","owner":"18","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-06-15"},"publish_date":"2018-06-15","publish_status":"0","recid":"44006","relation_version_is_last":true,"title":["クレーン荷物吊り上げ時の偏心検出システム(第1報): 基本構成とモデル実験"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2024-06-20T06:21:30.330465+00:00"}