{"created":"2023-07-27T06:50:56.828713+00:00","id":44148,"links":{},"metadata":{"_buckets":{"deposit":"1afc49de-17a3-4556-b83b-13946b23df6a"},"_deposit":{"created_by":18,"id":"44148","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"44148"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00044148","sets":["1132:1133:1134"]},"author_link":["74099","74097","74096","20280","74098","74160","74101","74100"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"198","bibliographicPageStart":"187","bibliographicVolumeNumber":"26","bibliographic_titles":[{"bibliographic_title":"医学物理"},{"bibliographic_title":"Japanese journal of medical physics","bibliographic_titleLang":"en"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"武村, 哲浩"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"鈴木, 正行"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"原内, 一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"奥村, 祐悠"}],"nameIdentifiers":[{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To improve the accuracy and robustness of 2D/3D registration of digital subtraction angiography images and magnetic resonance angiography (MRA) data , we have developed an automatic method for anatomical labeling of the cerebral arteries in MRA data. The anatomical labeling method is a location-based method which segments an artery tree to branches and classifies the branches into labeled segments , i.e., internal carotid arteries (ICA), basilar artery (BA), middle cerebral arteries (MCA) , Al segments of the anterior cerebral artery (ACA(A1)), other segments of the anterior cerebral artery (ACA), posterior communication arteries (PcomA) and posterior cerebral arteries (PCA), according to their location. Arteries were extracted from MRA data for this labeling method by the region-growing technique . Fifteen cases were examined to evaluate the method accuracy. The number of correctly segmented voxels in each artery segment was determined, and the correct labeling percentage was calculated based on the total number of voxels of the artery . Mean percentages were as follows: ACA, 82.7%; Right (R-) ACA(A1) , 47.1%; Left (L-) ACA(A1), 46.1%; R-MCA, 80.4%; L-MCA, 74.1%; R-PcomA , 0.0%; L-PcomA, 3.3%; R-PCA, 60.3%; LPCA, 66.9%; R-ICA, 90.7%; L-ICA, 90.7%; BA, 89.9%; and total arteries, 84.1%. The ACA, MCA, ICA and BA were consistently identified correctly .","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学医薬保健研究域保健学系","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00050490","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Japan Society of Medical Physics 日本医学物理学会"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.11323/jjmp2000.26.4_187 ","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.jsmp.org/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsmp.org/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © Japan Society of Medical Physics 日本医学物理学会"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA11580542","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1345-5354","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Takemura, Akihiro"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Suzuki, Masayuki"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Harauchi, Hajime"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Okumura, Yusuke"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-04-13"}],"displaytype":"detail","filename":"ME-PR-TAKEMURA-A-187.pdf","filesize":[{"value":"4.4 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"ME-PR-TAKEMURA-A-187.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/44148/files/ME-PR-TAKEMURA-A-187.pdf"},"version_id":"6922c8d0-33dc-40f3-a50a-7328f6e50a40"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Automatic Anatomical Labeling Method of Cerebral Arteries in MR-Angiography Data Set","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Automatic Anatomical Labeling Method of Cerebral Arteries in MR-Angiography Data Set"}]},"item_type_id":"4","owner":"18","path":["1134"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-04-13"},"publish_date":"2018-04-13","publish_status":"0","recid":"44148","relation_version_is_last":true,"title":["Automatic Anatomical Labeling Method of Cerebral Arteries in MR-Angiography Data Set"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T17:35:35.693024+00:00"}