@techreport{oai:kanazawa-u.repo.nii.ac.jp:00044447, month = {May}, note = {ECG同期冠動脈CTAを施行する場合であっても,撮影法,心拍数によって胸部臓器の吸収線量は大きく異なることが確認された.BEIR VII Phase 2 reportより推定した肺がんの発生リスクは,ECG同期高速二重螺旋スキャン法では0.006%,ECG同期非螺旋スキャン法では0.034%,ECG同期螺旋スキャン法では0.073%であった.ECG同期冠動脈CTAを施行する際には,それぞれの撮影方式は適切に選択されるべきであり,ECG同期高速二重螺旋スキャン法では,画質の劣化を伴うことへのリスクも注意深く考慮する必要がある., It was confirmed that radiation doses absorbed by thoracic organs during ECG-gated coronary CTA were different according to the acquisition technique and heart rate. The estimated lifetime attributable risks of lung cancer incidence in patients who underwent ECG-gated coronary CTA were 0.006% with the ECG-gated high-pitch dual-spiral mode, 0.034% with the ECG-gated step-and-shoot mode, and 0.073% with the ECG-gated low-pitch spiral mode, respectively. Each acquisition mode should be selected appropriately, and it is necessary to carefully consider the risk for deterioration of image quality when the ECG-gated high-pitch dual-spiral mode is applied., 出典:研究課題「ECG 同期冠動脈 CTAにおける臓器吸収線量の評価」課題番号21791175 (KAKEN:科学研究費助成事業データベース(国立情報学研究所)) (https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-21791175/21791175seika/)を加工して作成, 金沢大学医薬保健研究域保健学系}, title = {ECG 同期冠動脈 CTAにおける臓器吸収線量の評価}, year = {2012} }