{"created":"2023-07-27T06:51:43.116071+00:00","id":45246,"links":{},"metadata":{"_buckets":{"deposit":"9fa9798f-5037-4e8f-9625-d9d2676ad556"},"_deposit":{"created_by":18,"id":"45246","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"45246"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00045246","sets":["2812:2813:2819"]},"author_link":["2076","45819"],"item_9_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-09-21","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"4p.","bibliographicVolumeNumber":"2013-04-01 - 2016-03-31","bibliographic_titles":[{"bibliographic_title":"平成26(2014)年度 科学研究費補助金 基盤研究(C) 研究成果報告書"},{"bibliographic_title":"2014 Fiscal Year Final Research Report","bibliographic_titleLang":"en"}]}]},"item_9_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{}],"nameIdentifiers":[{},{},{}]}]},"item_9_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"0.5マイクログラムパクリタキセル含有ハニカムフィルムは長期においても、眼圧下降効果を維持しつつ濾過胞瘢痕化抑制及び有血管濾過胞形成に有用であった。マイトマイシンCと比較した場合、眼圧下降効果は同等で有血管性濾過胞形成には著明な効果を示したが、長期的にはマイトマイシンCより濾過胞が瘢痕化する傾向にあった。また本フィルムは術後4種間まで薬剤を溶出しており、創傷治癒反応抑制に十分な速度で溶出した。","subitem_description_type":"Abstract"},{"subitem_description":"Pacritaxel released from honeycomb-patterned film promoted bleb survival and IOP decrease. The lowest dose of pacritaxel (0.5 µg) was effective at preventing bleb avascularity without compromising filtration. Compared with mitomycin C eyes, bleb became flattened in pacritaxel-treated eyes. In addtion, the release profile of pacritaxel in our honeycomb-patterned film carrier may be appropriate to suppress the major proliferative stage of wound healing.","subitem_description_type":"Abstract"}]},"item_9_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"出典:研究課題「実験的緑内障濾過手術におけるハニカムフィルムの有用性」課題番号25462706\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所))\n(https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-25462706/25462706seika/)を加工して作成","subitem_description_type":"Other"}]},"item_9_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学附属病院眼科","subitem_description_type":"Other"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00051585","subitem_identifier_reg_type":"JaLC"}]},"item_9_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/search/?qm=10361990"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/search/?qm=10361990","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-25462706/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-25462706/","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-25462706/25462706seika/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-25462706/25462706seika/","subitem_relation_type_select":"URI"}}]},"item_9_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-07-09"}],"displaytype":"detail","filename":"HO-PR-OKUDA-T-kaken 2016-4p.pdf","filesize":[{"value":"175.7 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"HO-PR-OKUDA-T-kaken 2016-4p.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/45246/files/HO-PR-OKUDA-T-kaken 2016-4p.pdf"},"version_id":"82c83435-4bf0-4d1f-994c-9c70c28948c5"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"実験的緑内障濾過手術におけるハニカムフィルムの有用性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"実験的緑内障濾過手術におけるハニカムフィルムの有用性"},{"subitem_title":"A honeycom-patterned film in experimental glaucoma filtration surgery","subitem_title_language":"en"}]},"item_type_id":"9","owner":"18","path":["2819"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-07-09"},"publish_date":"2018-07-09","publish_status":"0","recid":"45246","relation_version_is_last":true,"title":["実験的緑内障濾過手術におけるハニカムフィルムの有用性"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T10:43:05.161553+00:00"}