{"created":"2023-07-27T06:52:21.499149+00:00","id":46227,"links":{},"metadata":{"_buckets":{"deposit":"decca728-4256-4516-92af-73f04488fe1f"},"_deposit":{"created_by":18,"id":"46227","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"46227"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00046227","sets":["2812:2813:2817"]},"author_link":["261","80113"],"item_9_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-06-16","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"4p.","bibliographicVolumeNumber":"2015-04-01 - 2017-03-31","bibliographic_titles":[{"bibliographic_title":"平成28(2016)年度 科学研究費補助金 挑戦的萌芽研究 研究成果報告書"},{"bibliographic_title":"2016 Fiscal Year Final Research Report","bibliographic_titleLang":"en"}]}]},"item_9_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{}],"nameIdentifiers":[{},{}]}]},"item_9_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"高周波集積回路技術を利用した生体の透過画像計測の基礎を確立するための研究を実施した。具体的な応用として、生体の骨密度計測やCT像の取得を想定し、ミリ波~サブミリ波帯の光源と受光器の実現方法について検討を行った。本研究の特長は、従来のX線や赤外光非侵襲計測システムとは異なり、量産が可能な最先端のシリコン集積回路技術を利用した光源と受光器を使用し、生体への負荷がなく、小型で取り扱いの容易な計測システムを構成することを目的としている点にある。テラヘルツ領域での、生体組織の透過スペクトラムの計測、光源と受光器の回路の提案および試作などを行った。","subitem_description_type":"Abstract"},{"subitem_description":"The study of the biological transmission measurement system based on the RF integrated circuits has been conducted. In this study, the implementation method of the source and receiver for millimeter and sub-millimeter wave is proposed to measure the bone density and to obtain the CT images. The proposed measurement method is less harmful to the humans and the measurement system is the small-sized and with easy-handling. In the millimeter and sub-millimeter wave, the transmission spectrum of meat and bone was measured with the terahertz spectroscopic instrument.","subitem_description_type":"Abstract"}]},"item_9_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"研究課題/領域番号:15K12504, 研究期間(年度):2015-04-01 - 2017-03-31","subitem_description_type":"Other"},{"subitem_description":"出典:「高周波集積回路技術を利用した生体透過計測法の基礎の確立」研究成果報告書 課題番号15K12504\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所)) \n(https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K12504/15K12504seika/)を加工して作成","subitem_description_type":"Other"}]},"item_9_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学理工研究域電子情報通信学系","subitem_description_type":"Other"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00052560","subitem_identifier_reg_type":"JaLC"}]},"item_9_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/search/?qm=10214785"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/search/?qm=10214785","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15K12504/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15K12504/","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K12504/15K12504seika/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K12504/15K12504seika/","subitem_relation_type_select":"URI"}}]},"item_9_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-10-25"}],"displaytype":"detail","filename":"TE-PR-KITAGAWA-A-kaken 2017-4p.pdf","filesize":[{"value":"125.8 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"TE-PR-KITAGAWA-A-kaken 2017-4p.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/46227/files/TE-PR-KITAGAWA-A-kaken 2017-4p.pdf"},"version_id":"6667202a-e03a-47e5-bf8b-3fc58947d96a"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"高周波集積回路技術を利用した生体透過計測法の基礎の確立","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高周波集積回路技術を利用した生体透過計測法の基礎の確立"},{"subitem_title":"Study of biological transmission measurement system by RF integrated circuits","subitem_title_language":"en"}]},"item_type_id":"9","owner":"18","path":["2817"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-10-25"},"publish_date":"2018-10-25","publish_status":"0","recid":"46227","relation_version_is_last":true,"title":["高周波集積回路技術を利用した生体透過計測法の基礎の確立"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T11:09:05.970186+00:00"}