{"created":"2023-07-27T06:54:29.909991+00:00","id":49830,"links":{},"metadata":{"_buckets":{"deposit":"45ebb355-1dee-4ca1-8bdb-19343f4f914d"},"_deposit":{"created_by":18,"id":"49830","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"49830"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00049830","sets":["1132:1133:1134"]},"author_link":["89970","2771","77366","89971","89969","89974","89977","89968","89972","77367","72008","89973"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-11-15","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"8p.","bibliographic_titles":[{"bibliographic_title":"Journal of Patient Safety"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"向井, 加奈恵"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"中島, 由加里"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"中谷, 壽男"}],"nameIdentifiers":[{},{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Objective The aim of the present observational study was to identify safe and suitable venipuncture sites for nursing in the clinical setting using ultrasonography to measure the depth and cross-sectional area of each superficial vein before and after tourniquet application as well as the distance between each superficial vein and the median nerve or brachial artery.\n\\nMethods and Results Twenty healthy volunteers (21.8 [0.6] y) were recruited. The visible rate of each superficial vein before and after tourniquet application was 65% for the basilic vein, 90% to 95% for the median cubital vein, and 65% to 80% for the cephalic vein. The cross-sectional area of the median cubital vein after tourniquet application was significantly larger than that of the basilic vein and cephalic vein. The distance between the basilic vein or median cubital vein and median nerve was significantly smaller than that between the cephalic vein and median nerve. The distance between the basilic vein or median cubital vein and brachial artery was significantly smaller than that between the cephalic vein and brachial artery.\n\\nConclusions These results demonstrated that the cephalic vein at the cubital fossa is a relatively safe venipuncture site because of its distance from the median nerve and brachial artery. When puncturing the cephalic vein is difficult because it is not visible, the median cubital vein at the cubital fossa may be selected for venipuncture due to its cross-sectional area and visibility; however, care is needed to avoid penetrating the vein because the median nerve and brachial artery are located underneath.","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学医薬保健研究域保健学系","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00056142","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"National Patient Safety Foundation / Lippincott, Williams & Wilkins"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1097/PTS.0000000000000441","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://journals.lww.com/journalpatientsafety/Abstract/publishahead/Safety_of_Venipuncture_Sites_at_the_Cubital_Fossa.99416.aspx"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://journals.lww.com/journalpatientsafety/Abstract/publishahead/Safety_of_Venipuncture_Sites_at_the_Cubital_Fossa.99416.aspx","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal."},{"subitem_rights":"Copyright © 2019 Wolters Kluwer Health, Inc."}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA12157570","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1549-8417","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Mukai, Kanae"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Nakajima, Yukari"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Nakano, Tomotaka"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Okuhira, Manami"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kasashima, Aya"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hayashi, Rina"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamashita, Misaki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Urai, Tamae"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakatani, Toshio"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-11-22"}],"displaytype":"detail","filename":"ME-PR-NAKATANI-T-99416.pdf","filesize":[{"value":"602.6 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"ME-PR-NAKATANI-T-99416.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/49830/files/ME-PR-NAKATANI-T-99416.pdf"},"version_id":"7af02a59-b33f-4a9c-b521-75fb686b05ab"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Safety of venipuncture sites at the cubital fossa as informed by ultrasonography","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Safety of venipuncture sites at the cubital fossa as informed by ultrasonography"}]},"item_type_id":"4","owner":"18","path":["1134"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-11-22"},"publish_date":"2019-11-22","publish_status":"0","recid":"49830","relation_version_is_last":true,"title":["Safety of venipuncture sites at the cubital fossa as informed by ultrasonography"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T15:58:53.680764+00:00"}