{"created":"2023-07-27T06:55:35.502799+00:00","id":51657,"links":{},"metadata":{"_buckets":{"deposit":"0db03506-18f8-42b3-90b8-1a74b08fb27b"},"_deposit":{"created_by":18,"id":"51657","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"51657"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00051657","sets":["2812:2813:3929"]},"author_link":["299","85235"],"item_9_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-05-09","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"15p.","bibliographicVolumeNumber":"2016-04-01 - 2020-03-31","bibliographic_titles":[{"bibliographic_title":"令和1(2019)年度 科学研究費補助金 基盤研究(C) 研究成果報告書"},{"bibliographic_title":"2019 Fiscal Year Final Research Report","bibliographic_titleLang":"en"}]}]},"item_9_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{}],"nameIdentifiers":[{},{}]}]},"item_9_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"近年,1枚の胸部X線写真から画像処理により肋骨陰影のみを選択的に減弱できるようになった.呼吸過程を撮影した胸部X線動画像に適用することで,肋骨陰影のない胸部X線動画像(=軟組織X線動画像)を作成できる.本研究では,軟組織X線動画像を対象に,肺の動的変化から肺機能評価を可能にする画像解析技術の開発に取り組んだ.研究期間内に,①軟組織X線動画像の作成,②肺(特に,軟組織成分)の動的変化を定量化する画像解析プログラムの開発,③定量化した肺の動的変化の理解,④診断ロジックの検証,⑤診断支援システムの開発を行った.","subitem_description_type":"Abstract"},{"subitem_description":"Recent digital image-processing allows to create a soft-tissue image by suppressing the rib shadows on a chest radiograph, resulting in an early detection of lung cancer. Therefore, dynamic soft-tissue images can be provided by applying this technique to sequential chest radiographs during respiration. The aim of this study was to develop computerized methods for evaluating pulmonary function based on dynamic changes on the projected lungs. During our research period, we have achieved five tasks; 1) creation of dynamic soft-tissue images, 2) development of computerized methods to quantify dynamic changes on the projected lungs, 3) assessment of the resulting quantified dynamic changes, 4) validation of diagnostic criteria, and 5) development of preliminary computer aided diagnosis system for dynamic chest radiographs.","subitem_description_type":"Abstract"}]},"item_9_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"研究課題/領域番号:16K10271, 研究期間(年度):2016-04-01 - 2020-03-31","subitem_description_type":"Other"},{"subitem_description":"出典:「低線量X線動画イメージングによる肺機能診断法の開発」研究成果報告書 課題番号16K10271\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所))\n(https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K10271/16K10271seika/)を加工して作成","subitem_description_type":"Other"}]},"item_9_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学医薬保健研究域保健学系","subitem_description_type":"Other"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00057960","subitem_identifier_reg_type":"JaLC"}]},"item_9_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/search/?qm=40361985"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/search/?qm=40361985","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-16K10271/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-16K10271/","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K10271/16K10271seika/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K10271/16K10271seika/","subitem_relation_type_select":"URI"}}]},"item_9_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-04-26"}],"displaytype":"detail","filename":"ME-PR-TANAKA-R-kaken 2020-15p.pdf","filesize":[{"value":"514.7 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"ME-PR-TANAKA-R-kaken 2020-15p.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/51657/files/ME-PR-TANAKA-R-kaken 2020-15p.pdf"},"version_id":"1713a9e1-4e7b-446a-bf91-c3d3e1eb69c4"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"低線量X線動画イメージングによる肺機能診断法の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"低線量X線動画イメージングによる肺機能診断法の開発"},{"subitem_title":"Development of pulmonary function diagnosis based on low-dose X-ray imaging","subitem_title_language":"en"}]},"item_type_id":"9","owner":"18","path":["3929"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-04-26"},"publish_date":"2021-04-26","publish_status":"0","recid":"51657","relation_version_is_last":true,"title":["低線量X線動画イメージングによる肺機能診断法の開発"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T14:05:29.119702+00:00"}