{"created":"2023-07-27T06:55:59.122973+00:00","id":52503,"links":{},"metadata":{"_buckets":{"deposit":"0bb9c853-c67e-4487-99bd-f20bc3687d32"},"_deposit":{"created_by":18,"id":"52503","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"52503"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00052503","sets":["2812:2813:3929"]},"author_link":["709"],"item_9_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-05-09","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"8p.","bibliographicVolumeNumber":"2016-04-01 – 2020-03-31","bibliographic_titles":[{"bibliographic_title":"令和1(2019)年度 科学研究費補助金 挑戦的萌芽研究 研究成果報告書"},{"bibliographic_title":"2019 Fiscal Year Final Research Report","bibliographic_titleLang":"en"}]}]},"item_9_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{}],"nameIdentifiers":[{},{},{},{}]}]},"item_9_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"理論的検討として、細長い細胞の束であるという骨格筋の組織学的特徴を反映させて骨格筋の電気インピーダンスを計算する独自の等価要素法計算技法、およびT管系の影響を式で表して数値計算に組み込む技法を開発した。これらの計算技法を活用して先行研究の実験結果を解析し、電気インピーダンスの変化から骨格筋の組織学的変化を推定できることを示した。さらに、計測法、計測結果解析法開発の基礎的検討に活用した。\n実験的検討として、現有の複数の計測装置を用いてコンデンサーと抵抗素子を組み合わせて作成した回路を測定し、必要な周波数範囲で適切な4端子法計測が実行できるかどうか性能評価した。","subitem_description_type":"Abstract"},{"subitem_description":"As theoretical examinations, an unique technique of the finite-difference method using equivalent elements was developed to evaluate the electrical impedance of muscles, by taking account of the histological structure of the muscles, in which long tubular muscle cells are bundled. Additionally, a technique for representing the effects of the T-tubules in the calculations by analytical relations was developed. Theoretical analyses of reported experimental results using these techniques revealed the histological origin of the observed changes in the impedance of the muscles. The techniques were also utilized for preliminary examinations for experimental methods and analysis methods of experimental data.\nAs experimental examinations, the impedance of electric circuits consisting of capacitors and resistors were measured to examine whether measuring instruments could be used in the “four-terminal method” measurements in a wide frequency region.","subitem_description_type":"Abstract"}]},"item_9_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"研究課題/領域番号:16K12928, 研究期間(年度):2016-04-01 – 2020-03-31","subitem_description_type":"Other"},{"subitem_description":"出典:「電気インピーダンス法を用いた骨格筋緊張度の定量的な評価方法の開発」研究成果報告書 課題番号16K12928\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所))\n(https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-16K12928/16K12928seika/)を加工して作成","subitem_description_type":"Other"}]},"item_9_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学医薬保健研究域保健学系","subitem_description_type":"Other"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00058797","subitem_identifier_reg_type":"JaLC"}]},"item_9_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/ja/search/?kw=10163106"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/ja/search/?kw=10163106","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-16K12928/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-16K12928/","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-16K12928/16K12928seika/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-16K12928/16K12928seika/","subitem_relation_type_select":"URI"}}]},"item_9_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-05-13"}],"displaytype":"detail","filename":"ME-PR-SEKINE-K-kaken 2020-8p.pdf","filesize":[{"value":"539.7 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"ME-PR-SEKINE-K-kaken 2020-8p.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/52503/files/ME-PR-SEKINE-K-kaken 2020-8p.pdf"},"version_id":"2d1e4e91-d4e8-4c12-9130-7cfc72cb3a1f"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"電気インピーダンス法を用いた骨格筋緊張度の定量的な評価方法の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"電気インピーダンス法を用いた骨格筋緊張度の定量的な評価方法の開発"},{"subitem_title":"Developing methods for evaluating the muscle tonus objectively using bio-impedance-measurement techniques","subitem_title_language":"en"}]},"item_type_id":"9","owner":"18","path":["3929"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-05-13"},"publish_date":"2021-05-13","publish_status":"0","recid":"52503","relation_version_is_last":true,"title":["電気インピーダンス法を用いた骨格筋緊張度の定量的な評価方法の開発"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T14:09:17.222116+00:00"}