{"created":"2023-07-27T06:19:40.444327+00:00","id":593,"links":{},"metadata":{"_buckets":{"deposit":"d0ac5b5e-5bd2-4866-919a-e81a32530d19"},"_deposit":{"created_by":3,"id":"593","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"593"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00000593","sets":["11:12:16"]},"author_link":["3361","3362","168","3363"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-09-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"540","bibliographicPageStart":"533","bibliographicVolumeNumber":"26","bibliographic_titles":[{"bibliographic_title":"Journal of physiological anthropology and applied human science"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This study aimed to determine the accuracy of segmental body composition variables estimated by singlefrequency BIA with 8-point contact electrodes (SF-BIA8), compared with dual-energy X-ray absorptiometry (DXA). Subjects were 72 obese Japanese adults (43 males and 29 females) aged 30 to 66 years. Segmental body composition variables (fat free mass : FFM, fat mass : FM, and percent fat mass : %FAT) were measured by these techniques. The correlations between impedance values and FFM measured by DXA were calculated. To examine the consistency in predicted values (SF-BIAS) with the reference (DXA), significant mean differences were tested by t-test and the degree of the difference was assessed by effect size. Correlations between the reference and predicted values were calculated. Additionally, the standard error of estimation (SEE) when estimating the reference from the predictor and the relative value of the SEE to the mean value of the DXA measurement (%SEE) were calculated. Systematic error was examined by Bland-Altman plots. High correlations were found between impedance and FFM measured by SF-BIA8. FFM in the extremities showed high correlations with the reference values, but systematic error was found. SF-BIA8 tended to overestimate FFM in the trunk. The consistencies in %FAT and FM with the reference value are inferior to those for FFM, and SEE values in %FAT and FM were greater than those for FFM. The accuracy of the estimated values in the trunk (FFM, %FAT, and FM) are inferior to those of the total body and extremities.","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学人間社会研究域人間科学系","subitem_description_type":"Other"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本生理人類学会"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.2114/jpa2.26.533","subitem_relation_type_select":"DOI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本生理人類学会;本文データは日本生理人類学会の許諾に基づきCiNiiから複製したものである"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA11462444","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1345-3475","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sato, Susumu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Demura, Shinichi"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Kitabayashi, Tamotsu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Noguchi, Takanori"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-02"}],"displaytype":"detail","filename":"ED-PR-DEMURA-S-533.pdf","filesize":[{"value":"856.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ED-PR-DEMURA-S-533.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/593/files/ED-PR-DEMURA-S-533.pdf"},"version_id":"f703ce67-1dd4-4491-843b-b4668de8090b"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Segmental Body Composition Assessment for Obese Japanese Adults by Single-Frequency Bioelectrical Impedance Analysis with 8-point Contact Electrodes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Segmental Body Composition Assessment for Obese Japanese Adults by Single-Frequency Bioelectrical Impedance Analysis with 8-point Contact Electrodes"}]},"item_type_id":"4","owner":"3","path":["16"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-02"},"publish_date":"2017-10-02","publish_status":"0","recid":"593","relation_version_is_last":true,"title":["Segmental Body Composition Assessment for Obese Japanese Adults by Single-Frequency Bioelectrical Impedance Analysis with 8-point Contact Electrodes"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2024-05-09T02:51:23.655433+00:00"}