{"created":"2023-07-27T07:00:25.165663+00:00","id":60347,"links":{},"metadata":{"_buckets":{"deposit":"46afcdbd-b160-4984-b6d4-cec02bfd77a4"},"_deposit":{"created_by":18,"id":"60347","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"60347"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00060347","sets":["2812:2813:2840"]},"author_link":["106183","105755"],"item_9_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-06-07","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"2p.","bibliographicVolumeNumber":"1993","bibliographic_titles":[{"bibliographic_title":"平成5(1993)年度 科学研究費補助金 奨励研究(A) 研究概要"},{"bibliographic_title":"1993 Research Project Summary","bibliographic_titleLang":"en"}]}]},"item_9_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{}],"nameIdentifiers":[{},{}]}]},"item_9_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】活性型ビタミンD_3〔1,25(OH)_2D_3〕の血中レベルは、ビタミンD代謝異常を伴う各種疾患の診断指標として重要である。従来その測定は、主にニワトリ小腸あるいは受精卵十二指腸レセプターを用いるラジオレセプターアッセイ(RRA)により行われてきた。しかし、HPLCを含む多段階のクリーンアップ操作が不可欠で検体処理能力に難がある。この問題を解決するために、\"タンデム\"イムノアフィニティークロマトグラフィー(IAC)を新規な前処理法として開発し、そのヒト血漿RRAにおける有用性を検討した。\n【実験・結果】11alpha-Hemiglutaryloxy-25(OH)D_3(1)又は25(OH)D_33-hemisuccinate(2)をハプテンとして得られた抗体を不溶化し,選択性の異なるイムノカラム2種(1及び2)を調製した。ヒト血漿のエーテル抽出物をカラム1にアプライし,25%MeCN溶出画分をカラム2に適用した。20%アセトンで洗浄後,95%MeOHで吸着物を溶出し,本画分における1,25(OH)_2D_3,D_3,25(OH)D_3,24,25(OH)_2D_3の回収率を求めた。その結果,それぞれ68,0.6,2.6,1.1%の値が得られ,本IACが十分な選択性を有することが示された。そこで,健常人血漿を本IACで前処理したのち十二指腸レセプターを用いるRRAに付したところ,従来の報告と符合する値(33.5±8.9pg/ml)が得られた。また,添加回収,段階希釈などの試験結果も良好で,本IAC/RRA法の信頼性が確認された。さらに,慢性腎不全患者血漿についても良好な測定値が得られ,本症の鑑別診断に有用なことが確認された。\n【考察】今回開発した\"タンデム\"IACの導入により,HPLCの不必要な1,25(0H)_2D_3のRRAを開発することができた。本IACは精製効率と検体処理能力に優れ,RIA,GC-MSによる1,25(0H)_2D_3分析法の開発にも有用と期待される。","subitem_description_type":"Abstract"}]},"item_9_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"研究課題/領域番号:05771953, 研究期間(年度):1993","subitem_description_type":"Other"},{"subitem_description":"出典:研究課題「イムノアフィニティークロマトグラフィーを用いる活性型ビタミンD_3分析法の開発」課題番号05771953\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所)) \n(https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-05771953/)を加工して作成","subitem_description_type":"Other"}]},"item_9_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学薬学部","subitem_description_type":"Other"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00066595","subitem_identifier_reg_type":"JaLC"}]},"item_9_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/ja/search/?kw=90205477"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/ja/search/?kw=90205477","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-05771953/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-05771953/","subitem_relation_type_select":"URI"}}]},"item_9_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-07-01"}],"displaytype":"detail","filename":"PH-PR-KOBAYASHI-N-kaken 2018-2p.pdf","filesize":[{"value":"167.9 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"PH-PR-KOBAYASHI-N-kaken 2018-2p.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/60347/files/PH-PR-KOBAYASHI-N-kaken 2018-2p.pdf"},"version_id":"ab27cf87-8b43-4635-8bff-2a8fb8366ed9"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"イムノアフィニティークロマトグラフィーを用いる活性型ビタミンD_3分析法の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"イムノアフィニティークロマトグラフィーを用いる活性型ビタミンD_3分析法の開発"}]},"item_type_id":"9","owner":"18","path":["2840"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-07-01"},"publish_date":"2022-07-01","publish_status":"0","recid":"60347","relation_version_is_last":true,"title":["イムノアフィニティークロマトグラフィーを用いる活性型ビタミンD_3分析法の開発"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-07-27T12:41:49.287344+00:00"}