{"created":"2023-07-27T06:19:42.572608+00:00","id":644,"links":{},"metadata":{"_buckets":{"deposit":"2011ed14-9b2e-4753-a2ae-7d33c3fac92a"},"_deposit":{"created_by":3,"id":"644","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"644"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00000644","sets":["11:12:16"]},"author_link":["168","3471","3470"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-12-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"75","bibliographicPageStart":"71","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"Sport Sciences for Health"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The purpose of this study was to compare oxygenation kinetics measured by slightly different placements of a near-infrared spectroscopy (NIRS) probe during sustained isometric gripping. Oxygenation kinetics of sixteen young adult males was measured with two NIRS probes attached to the flexor carpiradialis muscle during gripping for 3 min. One probe (channel 1) was attached at one-third the length of a line from the medial epicondyle of the humerus to the styloid process of radius. Another probe (channel 2) was attached at the palmaris longus. Although the cross-correlation coefficients for the two probe placements regarding oxygenated hemoglobin (oxy-Hb/Mb), deoxygenated hemoglobin (deoxy-Hb/Mb) and tissue oxygenation saturation (StO2) were low (rxy, 0.119-0.405), Pearson's correlation coefficients for the times to reach almost steady state for these parameters were very high (oxy-Hb/Mb, r=0.878; deoxy-Hb/Mb, r=0.769; StO2, r=0.843; p<0.05). The difference of oxygenation kinetics between the probe placements may reflect the difference of fiber recruitment characteristics in the flexion muscle group. In conclusion, to obtain a stable measurement, it is important that the NIRS probe is placed at the same anatomical point. © Springer-Verlag Italia 2007.","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学人間社会研究域人間科学系","subitem_description_type":"Other"},{"subitem_description":"福井大学医学部","subitem_description_type":"Other"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Springer Verlag (Germany)"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1007/s11332-007-0042-2","subitem_relation_type_select":"DOI"}}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1824-7490","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Demura, Shinichi"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Yamaji, Shunsuke"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamada, Takayoshi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-02"}],"displaytype":"detail","filename":"ED-PR-DEMURA-YAMAJI-71.pdf","filesize":[{"value":"266.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ED-PR-DEMURA-YAMAJI-71.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/644/files/ED-PR-DEMURA-YAMAJI-71.pdf"},"version_id":"f8326111-3d9b-44e4-b505-da4eaaec11c6"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Comparison of oxygenation kinetics measured by different placements of the NIRS probe during sustained isometric gripping","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Comparison of oxygenation kinetics measured by different placements of the NIRS probe during sustained isometric gripping"}]},"item_type_id":"4","owner":"3","path":["16"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-02"},"publish_date":"2017-10-02","publish_status":"0","recid":"644","relation_version_is_last":true,"title":["Comparison of oxygenation kinetics measured by different placements of the NIRS probe during sustained isometric gripping"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T04:22:11.044202+00:00"}