{"created":"2023-07-27T06:24:35.089232+00:00","id":7549,"links":{},"metadata":{"_buckets":{"deposit":"d836993d-995d-4e42-8a66-5d6e41fe008e"},"_deposit":{"created_by":3,"id":"7549","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"7549"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00007549","sets":["934:935:936"]},"author_link":["10058","178","78","10059","42"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-01-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"3205","bibliographicPageStart":"3202","bibliographicVolumeNumber":"4030441","bibliographic_titles":[{"bibliographic_title":"Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings"}]}]},"item_4_description_16":{"attribute_name":"その他の識別子","attribute_value_mlt":[{"subitem_description":"4030441","subitem_description_type":"Other"}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Electrical impedance or admittance cardiography is a simple method for non-invasive, continuous measurement the stroke volume and cardiac output. For the Electrical impedance cardiography, the band-electrodes array proposed by Kubicek et al has been widely used, and various spot-electrodes array have been experimented in search of a less uncomfortable and equally reliable electrodes array that is easier to attach. From the uniformity of current distribution on the thorax, we have reinvestigated focusing on the measurement of contour maps of static and pulsatile components of a regional area along the medial line on the frontal part of the thorax. Consequently, the appropriate electrodes locations for current injection were determined as the back of an ear and on the lower abdomen, while those for voltage pick-up was on the medial portion at the level of clavicle and on the portion above the xiphisternum. Preliminary comparison experiments between the cardiac output values obtained by the electrical impedance cardiography and by a pulse dye-densitometry showed a fairy good agreement. © 2006 IEEE.","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"野川, 雅道","subitem_description_type":"Other"},{"subitem_description":"金沢大学大学院自然科学研究科知的システム創成","subitem_description_type":"Other"},{"subitem_description":"(財)石川県産業創出支援機構(ISICO)","subitem_description_type":"Other"},{"subitem_description":"石川ハイテク・センシング・クラスター","subitem_description_type":"Other"},{"subitem_description":"金沢大学工学部人間・機械工学科人間適応制御研究室","subitem_description_type":"Other"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers (IEEE)"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/iembs.2006.260748","subitem_relation_type_select":"DOI"}}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0589-1019","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Igarashi, Akira"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nogawa, Masamichi"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Yamakoshi, Takehiro"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Tanaka, Shinobu"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Yamakoshi, Ken-ichi"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-Ikarashi-A-3202.pdf","filesize":[{"value":"291.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-Ikarashi-A-3202.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/7549/files/TE-PR-Ikarashi-A-3202.pdf"},"version_id":"79088536-c6b1-4ab3-995d-bd28955a1498"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"An optimal spot-electrodes array for electrical impedance cardiography through determination of impedance mapping of a regional area along the medial line on the thorax","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"An optimal spot-electrodes array for electrical impedance cardiography through determination of impedance mapping of a regional area along the medial line on the thorax"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"7549","relation_version_is_last":true,"title":["An optimal spot-electrodes array for electrical impedance cardiography through determination of impedance mapping of a regional area along the medial line on the thorax"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T12:27:32.570020+00:00"}