{"created":"2023-07-27T06:24:55.638940+00:00","id":8017,"links":{},"metadata":{"_buckets":{"deposit":"ecd7cf0a-6fa5-4dd4-9ac5-cd9986cca05c"},"_deposit":{"created_by":3,"id":"8017","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8017"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00008017","sets":["934:935:936"]},"author_link":["11069","11071","11070","11068"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-06-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"32","bibliographicPageStart":"29","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"日本AEM学会誌 = Journal of the Japan Society of Applied Electromagnetics"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents the numerical analysis of magnetic pulse compression circuit taking into account eddy current loss of core. In order to be clear the loss contribution to the circuit performance, the magnetic nonlinearity and eddy current effect of core has been considered in the analysis, and the analysis was performed numerically by use of tableau method. On the view of 1) energy transfer efficiency, 2) current gain and 3) pulse compression ratio, the circuit performance has been investigated on the initial voltage of the start-up condensor and the setup time of core flux.","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学理工研究域電子情報学系","subitem_description_type":"Other"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本AEM学会"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10457520","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0919-4452","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩原, 正吉"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"山田, 外史"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"杉本, 博昭"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小嶋, 利幸"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-IWAHARA-M-29.pdf","filesize":[{"value":"286.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-IWAHARA-M-29.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/8017/files/TE-PR-IWAHARA-M-29.pdf"},"version_id":"fb5aa9d1-3297-44f8-92c7-3835ffd75986"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"磁心損失を考慮した磁気パルス圧縮回路の解析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"磁心損失を考慮した磁気パルス圧縮回路の解析"},{"subitem_title":"Analysis of Magnetic Pulse Compression Circuit taking into account Core Loss","subitem_title_language":"en"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"8017","relation_version_is_last":true,"title":["磁心損失を考慮した磁気パルス圧縮回路の解析"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T02:15:42.084797+00:00"}