{"created":"2023-07-27T06:25:26.596533+00:00","id":8741,"links":{},"metadata":{"_buckets":{"deposit":"b81e4d7c-bf69-4c78-a1e9-998fcbf94ae1"},"_deposit":{"created_by":3,"id":"8741","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8741"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00008741","sets":["934:935:936"]},"author_link":["73","846","776"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1988-10-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"506","bibliographicPageEnd":"2871","bibliographicPageStart":"2864","bibliographicVolumeNumber":"54","bibliographic_titles":[{"bibliographic_title":"日本機械学會論文集 B編 = Transactions of the Japan Society of Mechanical Engineers Series B"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"For the development of an air-cooled heat exchanger, mist cooled heat transfer on horizontal circular tubes exposed to the horizontal crossflow is discussed. Analytical and experimental studies were performed on the droplet collision on the tube, and the wetting conditions based on the droplets deposition and their fluidity. Heat transfer was clarified including a comparison with results in a vertical spray flow.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Mechanical Engineers = 日本機械学会"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1299/kikaib.54.2864","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/kikaib1979/-char/ja/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsme.or.jp/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110002401573","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © The Japan Society of Mechanical Engineers 日本機械学会"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN00187441","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5016","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松田, 理"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"滝本, 昭"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"林, 勇二郎"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-TAKIMOTO-A-2864.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-TAKIMOTO-A-2864.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/8741/files/TE-PR-TAKIMOTO-A-2864.pdf"},"version_id":"235b9c4b-c5bc-4d0b-a7f6-7dc3e48482d9"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ミスト冷却熱交換器に関する研究: 第4報,水平噴霧流下における円管からの熱伝達","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ミスト冷却熱交換器に関する研究: 第4報,水平噴霧流下における円管からの熱伝達"},{"subitem_title":"Study on Mist Cooling for Heat Exchangers: 4th Report, Mist Cooled Heat Transfer from a Circular Tube in a Horizontal Spray Flow","subitem_title_language":"en"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"8741","relation_version_is_last":true,"title":["ミスト冷却熱交換器に関する研究: 第4報,水平噴霧流下における円管からの熱伝達"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-05-13T05:46:11.583275+00:00"}