{"created":"2023-07-27T06:25:27.020041+00:00","id":8751,"links":{},"metadata":{"_buckets":{"deposit":"c209e227-a554-496c-ad8a-820f24a514ba"},"_deposit":{"created_by":3,"id":"8751","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8751"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00008751","sets":["934:935:936"]},"author_link":["601","7684"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-10-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageEnd":"1013","bibliographicPageStart":"1009","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"Radiation Measurements"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We report a novel two- and three-dimensional (2-D, 3-D) imaging detector based on the radiophotoluminescence (RPL) phenomenon in silver-activated phosphate glass (PG:Ag) and evaluate its dosimetric characteristics. A compact disk-type PG:Ag detector with a diameter of 80 mm was rotated at a rate of 400 rpm to read out the accumulated dose information and then remove the images for reuse. After X-ray exposure, three RPL dosimeter processes, i.e.; preheating, reading, and erasing, were carried out with only a UV laser at 375 nm by adjusting the stepwise output levels. The 3-D images and dose distributions were rapidly reconstructed with a high spatial resolution of 1 μm and a sensitivity of 1 mGy. © 2012 Elsevier Ltd. All rights reserved.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.radmeas.2012.09.003","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.elsevier.com/locate/issn/13504487","subitem_relation_type_select":"URI"}}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA11020151","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1350-4487","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kurobori, Toshio"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Nakamura, Shoichi"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"ED-PR-KUROBORI-T-1009.pdf","filesize":[{"value":"472.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ED-PR-KUROBORI-T-1009.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/8751/files/ED-PR-KUROBORI-T-1009.pdf"},"version_id":"64ff0eda-e8a1-4a38-9eaa-b89bf33eac8e"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"8751","relation_version_is_last":true,"title":["A novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T02:04:19.447645+00:00"}