@article{oai:kanazawa-u.repo.nii.ac.jp:00008768, author = {Al Huda, Mahfudz and 山田, 啓司 and 上田, 隆司}, issue = {633}, journal = {日本機械学會論文集 C編 = Transactions of the Japan Society of Mechanical Engineers Series C}, month = {May}, note = {The temperature of interface between a cutting tool and a chip in dry and wet turning is measured using two color pyrometer with a fused fiber coupler. A translucent Alumina sintered under HIP (Hot Isostatic Pressing) is used as the cutting tool, and 0.45% carbon steel (S45C) is used as a workpiece. The water soluble fluid (Sunlight TC-800) is used as the cutting fluid, and is introduced onto the rake surface of the tool with a nozzle (diameter: 5 mm). The infrared rays radiated and transmitted through the translucent tool are accepted by an optical fiber, and separated to two optical fibers at fused fiber coupler. Each fiber leads the infrared ray, respectively, to two infrared detectors of different spectral sensitivity. Temperature is obtained by calculating the ratio of the output voltage from these two detectorS. The result obtained are as follows: (1) The technique developed is suitable for measuring the interface temperature between a cutting tool and a chip. (2) The interface temperature is highly affected by the cutting speed, and the temperature increases very rapidly with the increase of cutting speed. (3) The interface temperature reduced 30°C in the wet cutting. Finally, the temperature distributions on the cutting tool and the work material are analyzed by using a finite element method (FEM). Good agreement is obtained between the analytical results and the experimental ones.}, pages = {2094--2101}, title = {旋削加工における工具-切りくず接触面温度の測定}, volume = {65}, year = {1999} }