{"created":"2023-07-27T06:25:29.392110+00:00","id":8807,"links":{},"metadata":{"_buckets":{"deposit":"0230162f-1c9b-458c-921a-4f74ff3d8230"},"_deposit":{"created_by":3,"id":"8807","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8807"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00008807","sets":["934:935:936"]},"author_link":["12469","12471","12468","12465","12467","12466","10974","12470","12464","12472"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-01-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"2065","bibliographicPageStart":"2062","bibliographicVolumeNumber":"39 IFMBE","bibliographic_titles":[{"bibliographic_title":"IFMBE Proceedings"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Motor racing athletes, especially Grand Touring (GT) car racing drivers in the closed-cockpit category, can face lifethreatening situations caused by heat stroke. In this paper, a novel continuous tympanic temperature monitoring system, that could help to reduce this risk, is presented. The system consists of an earpiece containing an infrared-radiation-type tympanic thermometer and a micro-speaker. We validated the reliability of the system for tympanic temperature monitoring in 10 healthy volunteers (21.8 ± 1.0 S.D. years) using a temperature-controlled water bath. In addition, we evaluated the usefulness of the system with 2 professional drivers under real racing conditions in the 2010 SUPER GT International Series. The results showed strong correlation between the infrared-radiation tympanic temperature obtained by the present system and both the direct tympanic temperature (r = 0.994, n = 1119, P < 0.001) and the sublingual temperature (r = 0.972, n = 1119, P < 0.001) as a reference temperature. The mean difference between these temperatures was +0.09°C, and -0.08°C, and 95 % confidence interval (equal to 1.96 S.D.) was 0.21°C, and 0.44°C, respectively. In the field test, involving real competitive racing under severe conditions on a racing circuit, the system functioned well. These results suggest that our novel system has an acceptable performance in a race setting as a reliable tympanic temperature monitor and could help to improve safety of motor sports. © 2013 Springer-Verlag.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Springer-Verlag"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1007/978-3-642-29305-4_541","subitem_relation_type_select":"DOI"}}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1680-0737","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Lee, Jihyoung"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsumura, Kenta"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamakoshi, Kenichi"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Rolfe, Peter J."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tanaka, Naoto"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamakoshi, Yasuhiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takahashi, K."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kim, Kyungho"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hirose, H."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamakoshi, Takehiro"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-YAMAKOSHI-T-2062.pdf","filesize":[{"value":"361.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-YAMAKOSHI-T-2062.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/8807/files/TE-PR-YAMAKOSHI-T-2062.pdf"},"version_id":"fe3e2316-a806-44a0-8762-2f700f31634b"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of a novel tympanic temperature monitoring system for GT car racing athletes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a novel tympanic temperature monitoring system for GT car racing athletes"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"8807","relation_version_is_last":true,"title":["Development of a novel tympanic temperature monitoring system for GT car racing athletes"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T02:03:27.605026+00:00"}