{"created":"2023-07-27T06:25:35.090806+00:00","id":8943,"links":{},"metadata":{"_buckets":{"deposit":"0b5b6998-3384-4f84-a122-562a5c7bbe93"},"_deposit":{"created_by":3,"id":"8943","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8943"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00008943","sets":["934:935:936"]},"author_link":["11069","12719","189","12720"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"355","bibliographicPageStart":"352","bibliographicVolumeNumber":"21","bibliographic_titles":[{"bibliographic_title":"日本AEM学会誌 = Journal of the Japan Society of Applied Electromagnetics"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Giant magnetostrictive actuator has potential for producing a huge stress and minute stroke unlike electromagnetic actuators using electromagnetic force. We proposed the powerful generation of cavitation in water medium driven by the actuator. The collapse of cavitation generates pulse shock wave and also brings about radicals generating by addition of titanium oxide. The previous researches show the generation of cavitation and radicals based on the methylene blue test method, and the destructive influence of both virus and bacteria was recognized. The paper proposes a new apparatus of a circulation type system to aim the large capacity, and discusses the evaluation of sterilization and inactivation quantitatively. And we observed the biological condition of the cell to check the biological effect after sterilization.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本AEM学会 = The Japan Society of Applied Electromagnetics and Mechanics"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.14243/jsaem.21.352","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/jsaem/-char/ja/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsaem.gr.jp/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2013 The Japan Society of Applied Electromagnetics and Mechanics 日本AEM学会"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10457520","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0919-4452","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yamada, Sotoshi"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Nakamura, Shotarou"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kakikawa, Makiko"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Ueno, Toshiyuki"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-YAMADA-S-352.pdf","filesize":[{"value":"2.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-YAMADA-S-352.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/8943/files/TE-PR-YAMADA-S-352.pdf"},"version_id":"23f34f15-06b5-4a0f-b05b-8ecfdc8d70c8"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Sterilization Action on Cavitation Phenomenon Generated by Magnetostrictive Actuator","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Sterilization Action on Cavitation Phenomenon Generated by Magnetostrictive Actuator"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"8943","relation_version_is_last":true,"title":["Sterilization Action on Cavitation Phenomenon Generated by Magnetostrictive Actuator"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T02:01:33.280009+00:00"}