{"created":"2023-07-27T06:25:37.522693+00:00","id":8997,"links":{},"metadata":{"_buckets":{"deposit":"58983b8e-77d8-4072-a643-b00caef44d62"},"_deposit":{"created_by":3,"id":"8997","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8997"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00008997","sets":["934:935:936"]},"author_link":["178","12018","78","42","1064","11933","12782"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"976","bibliographicPageStart":"968","bibliographicVolumeNumber":"49","bibliographic_titles":[{"bibliographic_title":"生体医工学 = Transactions of Japanese Society for Medical and Biological Engineering : BME"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A new method is presented for the indirect measurement of systolic (SBP) and diastolic blood pressure (DBP) in the radial artery. We use the volume-oscillometric method with a wrist cuff and then, utilizing the photo-plethysmograph (PPG) signal together with cuff pressure measurements, we derive pressure-volume curves (PVC). The principle of this method, named “PVC inflection-point method”, is to identify the indirect SBP and DBP using the inflection-points of envelope curves overlaying respectively the lower and upper points of the photo-plethysmographic pulsation signals superimposed on an arterial volume signal during the volume-oscillometric procedure. The accuracy of the method was evaluated by comparison with measurements from arterial catheterization in two healthy subjects. During the test procedure, a prototype PPG sensor for the PVC inflection-point method was attached to the left wrist, and arterial catheterization of the right radial artery for was performed to obtain simultaneous blood pressure recordings. The Bland-Altman plots for the comparative analysis showed good agreements between the two methods for both SBP (+2.3±7.7 (mean±S.D.) mmHg) and DBP (-1.8±6.4mmHg) measurement. We conclude that the proposed PVC inflection-point method appears promising to determine indirect SBP and DBP values with appropriate accuracy for convenient and practical use.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本生体医工学会 = Japanese Society for Medical and Biological Engineering"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.11239/jsmbe.49.968","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://jsmbe.org/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/jsmbe/-char/ja/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 日本生体医工学会 Japanese Society for Medical and Biological Engineering"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA12119469","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1347-443X","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野川, 雅道"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"山越, 健弘"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松村, 健太"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"田中, 志信"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"小川, 充洋"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"本井, 幸介"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"山越, 憲一"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-NOGAWA-M-968.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-NOGAWA-M-968.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/8997/files/TE-PR-NOGAWA-M-968.pdf"},"version_id":"67264e0a-dd34-4ab4-acf9-a408cf6b2f96"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"圧—容積曲線変曲点に着目した容積振動型収縮期・拡張期血圧決定法の提案","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"圧—容積曲線変曲点に着目した容積振動型収縮期・拡張期血圧決定法の提案"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"8997","relation_version_is_last":true,"title":["圧—容積曲線変曲点に着目した容積振動型収縮期・拡張期血圧決定法の提案"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T02:00:40.971213+00:00"}