ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. B. 理工学域; 数物科学類・物質化学類・機械工学類・フロンティア工学類・電子情報通信学類・地球社会基盤学類・生命理工学類
  2. b 10. 学術雑誌掲載論文
  3. 1.査読済論文(工)

High Spatial Resolution Non-contact Measurement of Low Current Signal by Needle-Type GMR Probe

http://hdl.handle.net/2297/36994
http://hdl.handle.net/2297/36994
97eede3f-83b9-4e3a-8a57-570640345cc8
名前 / ファイル ライセンス アクション
TE-PR-YAMADA-S-386.pdf TE-PR-YAMADA-S-386.pdf (2.7 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル High Spatial Resolution Non-contact Measurement of Low Current Signal by Needle-Type GMR Probe
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
その他のタイトル
値 [特集] Asia-Pacific Symposium on Applied Electromagnetics and Mechanics
著者 Hoang, H.

× Hoang, H.

WEKO 12792

Hoang, H.

Search repository
Kakikawa, Makiko

× Kakikawa, Makiko

WEKO 189
e-Rad 10359713
金沢大学研究者情報 10359713
研究者番号 10359713

Kakikawa, Makiko

Search repository
Yamada, Sotoshi

× Yamada, Sotoshi

WEKO 11069
e-Rad 80019786
研究者番号 80019786

Yamada, Sotoshi

Search repository
書誌情報 日本AEM学会誌 = Journal of the Japan Society of Applied Electromagnetics

巻 21, 号 3, p. 386-390, 発行日 2013-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0919-4452
NCID
収録物識別子タイプ NCID
収録物識別子 AN10457520
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.14243/jsaem.21.386
出版者
出版者 日本AEM学会 = The Japan Society of Applied Electromagnetics and Mechanics
抄録
内容記述タイプ Abstract
内容記述 Miniaturization of electronic devices has making progress, resulting in smaller current flowing in extremely high-density LSI (large scale integration) or PCB (printed circuit board). However, measurements of such low local current have still been confronted with many difficulties because of the limitation on size of relatively large and cumbersome typical current sensors, lead to detecting general signals of a wide area. In this research, we propose the novel micron size and high sensitivity needle-type GMR probe in applications of non-contact measuring low currents coming from area narrower than 10-6 m2 with small signal crosstalk such as PCB current measurement and low bio magnetic signal detection. Low current of hundreds μA in high-density PCB tracks of 4×10-4 m pitch was measured with the signal crosstalk less than 10% and 5×10-6 A of nerve signal model was possible to be detected by micron size GMR probe.
権利
権利情報 Copyright © 2013 The Japan Society of Applied Electromagnetics and Mechanics 日本AEM学会
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連URI
識別子タイプ URI
関連識別子 https://www.jstage.jst.go.jp/browse/jsaem/-char/ja/
関連URI
識別子タイプ URI
関連識別子 http://www.jsaem.gr.jp/
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 02:00:35.699792
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3